Detailed Information

Cited 25 time in webofscience Cited 28 time in scopus
Metadata Downloads

Outcome and safety of self-expandable metallic stents for malignant colon obstruction: a Korean multicenter randomized prospective study

Full metadata record
DC Field Value Language
dc.contributor.authorCheung, Dae Young-
dc.contributor.authorKim, Jin Yong-
dc.contributor.authorHong, Sung Pil-
dc.contributor.authorJung, Min Kyu-
dc.contributor.authorYe, Byong Duk-
dc.contributor.authorKim, Sang Gyun-
dc.contributor.authorKim, Jin Hong-
dc.contributor.authorLee, Kang Moon-
dc.contributor.authorKim, Kyung Ho-
dc.contributor.authorBaik, Gwang Ho-
dc.contributor.authorKim, Ho Gak-
dc.contributor.authorEun, Chang Soo-
dc.contributor.authorKim, Tae Il-
dc.contributor.authorKim, Sang Woo-
dc.contributor.authorKim, Chang Duck-
dc.contributor.authorYang, Chang Heon-
dc.date.available2020-11-02T22:45:42Z-
dc.date.issued2012-11-
dc.identifier.issn0930-2794-
dc.identifier.issn1432-2218-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/11564-
dc.description.abstractNewly developed uncovered stents are designed to have varied radial force and high conformability to improve clinical outcome and safety. This study aimed to determine and compare the clinical outcome and safety of the Taewoong D-type uncovered stent and the Boston Scientific Wallfex stent. Patients with acute malignant colonic obstruction were treated with a colonic stent. For the purpose of palliation, patients were randomly allocated. For the purpose of bridging, the type of stent was determined by the discretion of the individual doctors. Technical and clinical success and complication occurrence were measured as primary outcomes. From 12 university hospitals, 123 patients with malignant colonic obstruction were enrolled. Of these 123 patients, 58 were treated with colonic stents for palliative purposes. The technical and clinical success rate was 100 % for both stents in the palliative group. Perforation occurred for one patient (3.6 %) in the Wallflex stent group (n = 28) on day 5 and for no patients in the D-type stent group (n = 30). Two cases of migration occurred: one with the Wallflex stent and one with the D-type stent. Stent restenosis occurred for one patient with the Wallflex stent. Preoperative bridging stents were placed in 65 patients. The median time to surgery was 10 days. The technical success rate was 93.4 %, and clinical success was achieved for 86.2 % of the patients. Perforation occurred for five patients: four with the Wallflex stent and one with the D-type stent. The efficacy and safety of the two stents did not differ statistically. The D-type colonic uncovered stent and the Wallflex colonic uncovered stent are effective and safe for both palliative and preoperative bridging therapy used to treat acute malignant colonic obstruction.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherSPRINGER-
dc.titleOutcome and safety of self-expandable metallic stents for malignant colon obstruction: a Korean multicenter randomized prospective study-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1007/s00464-012-2300-x-
dc.identifier.scopusid2-s2.0-84871615336-
dc.identifier.wosid000309879600011-
dc.identifier.bibliographicCitationSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, v.26, no.11, pp 3106 - 3113-
dc.citation.titleSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES-
dc.citation.volume26-
dc.citation.number11-
dc.citation.startPage3106-
dc.citation.endPage3113-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusMETASTATIC COLORECTAL-CANCER-
dc.subject.keywordPlusPHASE-III-
dc.subject.keywordPlusELECTIVE SURGERY-
dc.subject.keywordPlus1ST-LINE THERAPY-
dc.subject.keywordPlusLARGE-BOWEL-
dc.subject.keywordPlusSURVIVAL-
dc.subject.keywordPlusBEVACIZUMAB-
dc.subject.keywordPlusOXALIPLATIN-
dc.subject.keywordPlusLEUCOVORIN-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordAuthorColon cancer-
dc.subject.keywordAuthorSelf-expandable metal stent-
dc.subject.keywordAuthorObstruction-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Gastroenterology and Hepatology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chang Duck photo

Kim, Chang Duck
Others (Others(Others))
Read more

Altmetrics

Total Views & Downloads

BROWSE