Sensitivity of the suspected blood indicator: An experimental study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sung Chul | - |
dc.contributor.author | Chun, Hoon Jai | - |
dc.contributor.author | Kim, Eun Sun | - |
dc.contributor.author | Keum, Bora | - |
dc.contributor.author | Seo, Yeon Seok | - |
dc.contributor.author | Kim, Yong Sik | - |
dc.contributor.author | Jeen, Yoon Tae | - |
dc.contributor.author | Lee, Hong Sik | - |
dc.contributor.author | Um, Soon Ho | - |
dc.contributor.author | Kim, Chang Duck | - |
dc.contributor.author | Ryu, Ho Sang | - |
dc.date.available | 2020-11-02T23:44:39Z | - |
dc.date.created | 2020-10-16 | - |
dc.date.issued | 2012-08 | - |
dc.identifier.issn | 1007-9327 | - |
dc.identifier.uri | https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/11837 | - |
dc.description.abstract | AIM: To investigate whether suspected blood indicator (SBI) in capsule endoscopy (CE) is affected by background color and capsule passage velocity. METHODS: Experimental models of the small intestine constructed from paper in a variety of colors were used to simulate the background colors observed in CE images. The background colors studied included very pale yellow, yellow, very pale magenta, light grayish pink, burnt sienna, and deep and dark brown, and red spots were attached inside them. An endoscopic capsule was manually passed through the models. The rate of detection of the red spots by the SBI was evaluated based on the colors of the models and the capsule passage velocities (0.5 cm/s, 1 cm/s, and 2 cm/s). RESULTS: The rate of detection of the red spots by the SBI differed significantly according to the background color of the model (P < 0.001). Detection rates were highest for backgrounds of very pale magenta, burnt sienna, and yellow, in that order. They were lowest for backgrounds of dark brown and very pale yellow. The rate of detection of red spots by the SBI tended to decrease at rapid capsule passage velocities (1-2 cm/s) compared to slow velocities (0.5 cm/s) for backgrounds of very pale yellow (P = 0.042), yellow (P = 0.001), very pale magenta (P = 0.002), and burnt sienna (P = 0.001). No significant differences in the rate of detection were observed according to velocity for light grayish pink (P = 0.643) or dark brown (P = 0.396). CONCLUSION: SBI sensitivity was affected by background color and capsule passage velocity in the models. These findings may facilitate the rapid detection of bleeding lesions by CE. (C) 2012 Baishideng. All rights reserved. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | BAISHIDENG PUBLISHING GROUP INC | - |
dc.title | Sensitivity of the suspected blood indicator: An experimental study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Chun, Hoon Jai | - |
dc.contributor.affiliatedAuthor | Kim, Eun Sun | - |
dc.contributor.affiliatedAuthor | Jeen, Yoon Tae | - |
dc.contributor.affiliatedAuthor | Lee, Hong Sik | - |
dc.contributor.affiliatedAuthor | Um, Soon Ho | - |
dc.contributor.affiliatedAuthor | Kim, Chang Duck | - |
dc.contributor.affiliatedAuthor | Ryu, Ho Sang | - |
dc.identifier.doi | 10.3748/wjg.v18.i31.4169 | - |
dc.identifier.scopusid | 2-s2.0-84867697724 | - |
dc.identifier.wosid | 000307986800014 | - |
dc.identifier.bibliographicCitation | WORLD JOURNAL OF GASTROENTEROLOGY, v.18, no.31, pp.4169 - 4174 | - |
dc.relation.isPartOf | WORLD JOURNAL OF GASTROENTEROLOGY | - |
dc.citation.title | WORLD JOURNAL OF GASTROENTEROLOGY | - |
dc.citation.volume | 18 | - |
dc.citation.number | 31 | - |
dc.citation.startPage | 4169 | - |
dc.citation.endPage | 4174 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.subject.keywordPlus | VIDEO CAPSULE ENDOSCOPY | - |
dc.subject.keywordPlus | PUSH ENTEROSCOPY | - |
dc.subject.keywordPlus | SMALL-BOWEL | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordAuthor | Capsule endoscopy | - |
dc.subject.keywordAuthor | Suspected blood indicator | - |
dc.subject.keywordAuthor | Sensitivity | - |
dc.subject.keywordAuthor | Background color | - |
dc.subject.keywordAuthor | Passage velocity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
73, Goryeodae-ro, Seongbuk-gu, Seoul, Republic of Korea (02841) 82-2-2286-1265
COPYRIGHT 2020 KOREA UNIVERSITY MEDICAL LIBRARY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.