Detailed Information

Cited 29 time in webofscience Cited 29 time in scopus
Metadata Downloads

Inter-observer agreement on the interpretation of capsule endoscopy findings based on capsule endoscopy structured terminology: A multicenter study by the Korean Gut Image Study Group

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Byung Ik-
dc.contributor.authorLee, Si Hyung-
dc.contributor.authorMoon, Jeong-Seop-
dc.contributor.authorCheung, Dae Young-
dc.contributor.authorLee, In Seok-
dc.contributor.authorKim, Jin Oh-
dc.contributor.authorCheon, Jae Hee-
dc.contributor.authorPark, Cheol Hee-
dc.contributor.authorByeon, Jeong-Sik-
dc.contributor.authorPark, Youn Sun-
dc.contributor.authorShim, Ki-Nam-
dc.contributor.authorKim, Yong-Sik-
dc.contributor.authorKim, Kyung-Jo-
dc.contributor.authorLee, Kwang Jae-
dc.contributor.authorRyu, Ji-Kon-
dc.contributor.authorChang, Dong Kyung-
dc.contributor.authorChun, Hoon Jai-
dc.contributor.authorChoi, Myung-Gyu-
dc.date.available2020-11-03T06:49:00Z-
dc.date.issued2010-03-
dc.identifier.issn0036-5521-
dc.identifier.issn1502-7708-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/15092-
dc.description.abstractObjective. Capsule endoscopy (CE) is a novel investigation for the diagnosis of small-bowel disease but its interpretation is highly subjective. We studied the inter-observer agreement and accuracy of the interpretation of CE findings based on capsule endoscopy structured terminology (CEST). Material and methods. Fifty-six CE video clips were collected from eight university hospitals in South Korea and were independently reviewed by 13 gastroenterology experts and 10 trainees. All investigators recorded their findings based on CEST. To determine the accuracy of individual viewers, we defined the 'gold standard' as a joint review by four experts. Results. The 56 CE video clips included five normal cases, 19 cases of protruding lesions, 21 cases of depressed lesions, three cases of flat lesions, one case of abnormal mucosa, six cases with blood in the lumen, and one case of stenotic lumen. The overall mean accuracies for the experts and trainees were 74.3% +/- 22.6% and 61.7% +/- 25.4%, respectively. The overall accuracy for the trainee group was significantly lower than that for the expert group (P < 0.001), especially in normal, tumor, venous structure, and ulcer cases. The accuracies of the two groups varied with the CE findings. The accuracies were higher in cases with more prominent intraluminal changes (e.g. active small-bowel bleeding, ulcer, tumor, stenotic lumen). In contrast, subtle mucosal lesions, such as erosion, angioectasia, and diverticulum, had lower accuracies. The mean kappa values for the experts and trainees were 0.61 (range 0.39-0.97) and 0.46 (range 0.17-0.66), respectively. Conclusions. Our results showed that there was substantial agreement between experts and moderate agreement between trainees. In order to achieve higher accuracies and better inter-observer agreement, we need not only more experience with CE but also consensus regarding CEST terminology.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherTAYLOR & FRANCIS AS-
dc.titleInter-observer agreement on the interpretation of capsule endoscopy findings based on capsule endoscopy structured terminology: A multicenter study by the Korean Gut Image Study Group-
dc.typeArticle-
dc.publisher.location노르웨이-
dc.identifier.doi10.3109/00365520903521574-
dc.identifier.scopusid2-s2.0-77149135711-
dc.identifier.wosid000274856600015-
dc.identifier.bibliographicCitationSCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, v.45, no.3, pp 370 - 374-
dc.citation.titleSCANDINAVIAN JOURNAL OF GASTROENTEROLOGY-
dc.citation.volume45-
dc.citation.number3-
dc.citation.startPage370-
dc.citation.endPage374-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGastroenterology & Hepatology-
dc.relation.journalWebOfScienceCategoryGastroenterology & Hepatology-
dc.subject.keywordPlusPUSH-ENTEROSCOPY-
dc.subject.keywordPlusOBSCURE ORIGIN-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusNURSE-
dc.subject.keywordAuthorCapsule endoscopy analysis-
dc.subject.keywordAuthorInter-observer variability-
dc.subject.keywordAuthorSmall-bowel lesions-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Gastroenterology and Hepatology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chun, Hoon Jai photo

Chun, Hoon Jai
Anam Hospital (Department of Gastroenterology and Hepatology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE