Detailed Information

Cited 37 time in webofscience Cited 48 time in scopus
Metadata Downloads

Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures

Authors
Oh, Chang-WugKim, Jung-JaeByun, Young-SooOh, Jong-KeonKim, Joon-WooKim, Shin-YoonPark, Byung-ChulLee, Hyun-Joo
Issue Date
Dec-2009
Publisher
SPRINGER
Keywords
Subtrochanteric fracture; Minimally invasive plate osteosynthesis; Locking plate
Citation
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.129, no.12, pp 1659 - 1665
Pages
7
Indexed
SCIE
SCOPUS
Journal Title
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
Volume
129
Number
12
Start Page
1659
End Page
1665
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/15638
DOI
10.1007/s00402-009-0815-y
ISSN
0936-8051
1434-3916
Abstract
Intramedullary nailing is a mainstay in the treatment of subtrochanteric femoral fractures. But nailing is often unsuitable for difficult fracture patterns with comminution or when the medullary canal is narrow. The purpose of this study was to clarify the efficacy of minimally invasive plate osteosynthesis (MIPO) with locking compression plate in the treatment of subtrochanteric fractures. Twenty patients with subtrochanteric fractures (mean age 49.6 years) were prospectively treated using the MIPO technique using a locking plate. Indications of procedure were fractures with the greater trochanter or medial comminution, and multiple injured patients with a narrow femoral canal. According to the AO/OTA classification, there were three of type A, eight of type B, and nine of type C. All healed without bone graft, at an average of 20.1 weeks (range 16-32). With the exception of two patients with minor internal rotation deformity and one patient with 1 cm of shortening, most achieved acceptable alignment. All patients were able to walk with no or only a slight limp, and median Merle d'Aubigne score was 17.3 (15-18). Four patients complained of a slight pain in the trochanteric area due to plate prominence. The MIPO technique with a locking plate provides an alternative method for fixing subtrochanteric femur fractures, when IM nailing is inappropriate. This technique provides stable fixation, with a high union rate and a minimal complication rate.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jong Keon photo

Oh, Jong Keon
Guro Hospital (Department of Orthopedic Surgery, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE