Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Assessment of left ventricular function by analysis of volume-time curves of 16 segments with real-time three dimensional echocardiography: Left ventricular asynchrony as a clinical parameter for patients with heart failure

Authors
Park S.-M.Kim G.-C.Jeon M.-J.Lee C.-K.Kim D.-H.Park K.-S.Lee W.-H.Kwan J.
Issue Date
2006
Publisher
Korean Society of Circulation
Keywords
Echocardiography; Heart failure
Citation
Korean Circulation Journal, v.36, no.10, pp 669 - 675
Pages
7
Indexed
SCOPUS
KCI
Journal Title
Korean Circulation Journal
Volume
36
Number
10
Start Page
669
End Page
675
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/19210
DOI
10.4070/kcj.2006.36.10.669
ISSN
1738-5520
1738-5555
Abstract
Background and Objectives : Recent technical developments with high-resolution real-time 3-dimensional echocardiography (RT3DE) have facilitated the acquisition of high quality images and the analysis of segmental volume-time curves (VTCs). The purposes of this study were to assess left ventricular (LV) asynchrony with using the VTCs of 16 segments by RT3DE and to compare this with tissue Doppler imaging (TDI) as a clinical parameter. Subjects and Methods : Twenty-three heart failure (HF) patients (LVEF: 25 ± 6%, age: 60 ± 13 years) and 16 normal controls underwent TDI and RT3DE at baseline and 1-year. The standard deviation (803) of the end systolic time to reach the minimal systolic volume for the 16 segments on VTCs was obtained by RT3DE. The standard deviation (SD2) of the electromechanical coupling time for the 8 segments was measured using TDI. Results : SD3 was markedly higher in the HF patients than that in the controls (7.7 ± 2.5 vs 1.5 ± 1.0%, respectively, p<0.01) and it increased as the LVEF decreased (r=-0.85, p<0.01). SD2 was also significantly higher in the HF patients (27.0±8.6 vs 12.6±5.0 msec, respectively, p<0.01) and it had good negative correlation with the LVEF (r=-0.72, p<0.01). SD3 was well correlated with SD2 (r=0.66, p<0.01). At 1-year, the HF patients with an increased LVEF showed a decreased SD3 (7/13). In contrast, the patients with a decreased LVEF had an increased SD3 (3/13). Conclusion : The analysis of VTCs for the 16 LV segments with using RT3DE from a single acoustic window may be a useful clinical parameter for evaluating the LV function, including LV asynchrony, the LV volume and the LVEF. © 2006, The Korean Society of Circulation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Cardiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Seong-Mi photo

Park, Seong-Mi
Anam Hospital (Department of Cardiology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE