Hybrid transgastric approach for the treatment of gastroesophageal junction pathologies

Authors
Gonzalez, C.Kwak, J. -M.Davrieux, F.Watanabe, R.Marescaux, J.Swanstrom, L. L.
Issue Date
Feb-2019
Publisher
OXFORD UNIV PRESS INC
Keywords
fundoplication; GERD; hybrid surgery; laparoendoscopic collaborative surgery
Citation
DISEASES OF THE ESOPHAGUS, v.32, no.2
Indexed
SCIE
SCOPUS
Journal Title
DISEASES OF THE ESOPHAGUS
Volume
32
Number
2
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/2456
DOI
10.1093/dote/doy095
ISSN
1120-8694
1442-2050
Abstract
Flexible endoscopy has evolved to the point that it includes many endoluminal procedures that once required open or laparoscopic surgery, for instance, antireflux surgery, pyloromyotomy, mucosal and submucosal tumor resections, and even full-thickness resection. However, these procedures remain technically demanding due to flexible technology issues: difficult imaging, limited energy devices, lack of staplers, unsatisfactory suturing abilities, and so on. Transgastric laparoscopy or hybrid laparoscopy/flex endoscopy has been described for almost two decades as an alternative to a pure endoluminal approach, mainly for pancreatic pseudocyst drainage and full-thickness and mucosal resection of various lesions. The approach has never been widely adopted mostly due to cumbersome and difficult to maintain methods of gastric access. We propose to expand the indications of transgastric laparoscopy by using novel endoscopically placed ports to replicate endoscopic procedures particularly in the difficult to access proximal stomach such as endoluminal antireflux surgery. Under general anesthesia, five female pigs (mean weight: 27.6 kg) had endoscopic placement of 3, 5 mm intragastric ports (Endo-TAGSS, Leakwood KS, USA) using a technique similar to percutaneous endoscopic gastrostomy. A 5-mm laparoscope was used for visualization. Laparoendoscopic-assisted plication of the gastroesophageal junction (GEJ) was performed using 3-0 interrupted sutures (Polysorb (R), Covidien, Mansfield, MA, USA). A functional lumen imagine probe (EndoFLIP R (R), Crospon, Inc., Galway, Ireland) was used to measure diameter, cross sectional area (CSA), distensibility, and compliance of GEJ before and after intervention. Once theTAGSS ports were removed, the gastrotomies were closed by using endoscopic over-the-scope clips. At the end of the procedure, animals were euthanized. Five laparoendoscopic-assisted endoluminal plications were performed. The mean operative time was 65.6 min (Endoscopic evaluation: 3.2 min, TAGSS Insertion: 11 min, EndoFLIP evaluation + GEJ Plication: 43.25 min, gastric wall closure: 15 minutes). In all cases, this technique was effective and allowed to achieve an adequate GEJ plication by endoscopic grading and EndoFLIP measurements. Median pre-plication GEJ diameter (D) and median pre-plication GEJ cross-sectional area (CSA) were 11.42 mm (8.6-13.6 mm) and 104.8 mm(2) (58-146 mm2). After the procedure, these values were decreased to 6.14 mm (5.7-6.6 mm) and 29.8 mm(2) (25-34 mm2) respectively (p = 0.0079). Median pre-plication distensibility (d) and compliance (C) were 7.87mm(2)/mmHg (2.4-22.69mm(2)/mmHg) and 190.56 mm(3)/mmHg (70.9502.8 mm(3)/mmHg). After the procedure, these values decreased to 1.5 mm(2)/mmHg (0.7-2.2 mm(2)/mmHg) and 52.17 mm(3)/mmHg (21.9-98.7 mm(3)/mmHg) respectively (p = 0.0317). No intraoperative events were observed. Endoscopically, all valves were felt to be transitioned from a Hill grade 3 (normal state for the animal model)
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Colon and Rectal Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwak, Jung Myun photo

Kwak, Jung Myun
Anam Hospital (Department of Colon and Rectal Surgery, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE