Improving the utilization of implantable cardioverter defibrillators for sudden cardiac arrest prevention (Improve SCA) in developing countries: Clinical characteristics and reasons for implantation refusal

Authors
Singh, BalbirZhang, ShuChing, Chi-KeongHuang, DejiaLiu, Yen-BinRodriguez, Diego A.Hussin, AzlanKim, Young-HoonChasnoits, Alexandr RobertovichCerkvenik, JeffreyMuckala, Katy A.Cheng, Alan
Issue Date
Dec-2018
Publisher
WILEY
Keywords
implantable cardioverter defibrillator; primary prevention; secondary prevention; sudden cardiac arrest; underutilization
Citation
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, v.41, no.12, pp 1619 - 1626
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY
Volume
41
Number
12
Start Page
1619
End Page
1626
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/2849
DOI
10.1111/pace.13526
ISSN
0147-8389
1540-8159
Abstract
Background Despite available evidence that implantable cardioverter defibrillators (ICDs) reduce all-cause mortality among patients at risk for sudden cardiac death, utilization of ICDs is low especially in developing countries. Objective To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries. Methods Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction < 25%, nonsustained ventricular tachycardia [NSVT], or frequent premature ventricular complexes) were further categorized as "1.5 PP patients." Candidates who declined implantation were asked for reasons for refusal. Baseline factors that may have influenced the implant decision were examined using logistic regression. Results Among 3892 patients, the implant refusal rate was 46.5% among PP patients (n = 2700), and 10.3% among SP patients (n = 1192). The most common refusal reason was inability to pay for the device (53.8%), followed by not believing in the benefits of the ICD (19.4%). Among PP ICD candidates, those with no syncope, no NSVT, no premature ventricular contractions, shorter QRS duration, no atrial arrhythmias, and no left bundle branch block were more likely to refuse implant. Among SP candidates, a history of cardiovascular surgery and no sinus node dysfunction were significant predictors of ICD refusal. Additionally, countries had significant differences in patient refusal rates among PP and SP groups. Conclusion Implant refusal among PP patients is high in many countries. Increased reimbursement and better awareness of the benefits of an ICD could increase their utilization.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Cardiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Young Hoon photo

Kim, Young Hoon
Anam Hospital (Department of Cardiology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE