Feasibility of Intraoperative Neuromonitoring During Thyroid Surgery Using Transcartilage Surface Recording Electrodes

Authors
Wu, Che-WeiChiang, Feng-YuRandolph, Gregory W.Dionigi, GianlorenzoKim, Hoon YubLin, Yi-ChuChen, Hui-ChunChen, Hsiu-YaKamani, DiptiTsai, Tsung-YiLu, I-ChengChang, Pi-Ying
Issue Date
Nov-2018
Publisher
MARY ANN LIEBERT, INC
Keywords
intraoperative neuromonitoring; thyroid surgery; recurrent laryngeal nerve; transcartilage recording; electromyography; surface electrode
Citation
THYROID, v.28, no.11, pp 1508 - 1516
Pages
9
Indexed
SCI
SCIE
SCOPUS
Journal Title
THYROID
Volume
28
Number
11
Start Page
1508
End Page
1516
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/2942
DOI
10.1089/thy.2017.0680
ISSN
1050-7256
1557-9077
Abstract
Background: Intraoperative neural monitoring (IONM) has gained widespread acceptance as an adjunct to the gold standard of visual identification of the recurrent laryngeal nerve (RLN) during thyroid surgery. Currently, laryngeal electromyography (EMG) recording during IONM is almost always performed using endotracheal tube (ETT) surface electrodes placed adjacent to vocal folds originating from the inner surface of the thyroid cartilage (TC). Therefore, it was hypothesized that surface recording electrodes placed on the outer surface of the TC should enable access to the EMG response of the vocal folds during IONM. The aim of this experimental study was to evaluate the feasibility of the transcartilage approach for laryngeal EMG recording during IONM. Methods: A porcine model (12 pigs and 24 RLN sides) with well established applicability in IONM research was used for the experiments. Both ETT electrodes adjacent to vocal folds and adhesive pre-gelled electrodes on the TC were used for EMG recording during IONM. Electrically evoked EMG signals detected by both electrode types were recorded and analyzed. EMG changes during tracheal displacement and RLN traction injury were compared. Results: Both the ETT and TC recording electrodes recorded typical laryngeal EMG waveforms evoked by a 1 mA stimulus current applied on both sides of the RLNs and vagus nerves (VNs). Under RLN stimulation, the mean EMG amplitudes recorded with the ETT and TC electrodes were 973 +/- 79 mu V and 695 +/- 150 mu V, respectively. Under VN stimulation, the mean amplitudes were 841 +/- 163 mu V and 607 +/- 162 mu V, respectively. When upward displacement of the trachea was experimentally induced, the TC electrodes showed less variation in recorded EMG signals compared to ETT electrodes. When RLN traction stress was experimentally induced, both the ETT and TC electrodes accurately recorded the typical EMG pattern of progressively degrading amplitude and gradual recovery after release of traction. Conclusions: This study confirms the feasibility of using transcartilage surface electrodes for recording laryngeal EMG signals evoked during IONM in an animal model. However, before practical application of this approach in clinical thyroid surgery, further studies are needed to improve electrode designs by optimizing their shapes and sizes, and increasing their adhesive stability and sensitivity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Anesthesiology and Pain Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hoon Yub photo

Kim, Hoon Yub
Anam Hospital (Department of Breast and Endocrine Surgery, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE