Detailed Information

Cited 4 time in webofscience Cited 3 time in scopus
Metadata Downloads

Ultrasound-Guided Injection of the Sternocleidomastoid Muscle: A Cadaveric Study with Implications for Chemodenervation

Authors
Kim, Beom SukKim, Da SomKang, SeokKim, Jae YoungKang, ByungheonRhyu, Im JooYoon, Joon Shik
Issue Date
May-2021
Publisher
WILEY
Citation
PM&R, v.13, no.5, pp 503 - 509
Pages
7
Indexed
SCIE
SCOPUS
Journal Title
PM&R
Volume
13
Number
5
Start Page
503
End Page
509
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/51648
DOI
10.1002/pmrj.12463
ISSN
1934-1482
1934-1563
Abstract
Background Ultrasound guidance may improve the accuracy of botulinum toxin injection, but studies of its potential for cervical dystonia treatment are lacking. Objective To determine the accuracy of ultrasound-guided injection in the sternocleidomastoid muscle (SCM). Design Observational study. Setting Tertiary care university hospital. Participants Eighteen embalmed cadavers. Interventions In total, 36 SCMs from 18 embalmed cadavers were examined. One physician performed ultrasound scans to divide each SCM into quarters and evaluated its cross-sectional area (CSA) and thickness at each of three meeting points between adjacent quarters. Under ultrasound guidance, another experienced physician injected methylene blue solution at one of the three points, using the in-plane technique (12 specimens per point; right SCM 3 mL, left SCM 5 mL). One anatomist dissected all cadavers and measured the distance of dye dispersion along the longitudinal axis of each muscle. Dispersion ratio was calculated as longitudinal dye dispersion divided by SCM length. Main Outcome Measures SCM thickness and CSA; dye dispersion patterns (dispersion distance and dispersion ratio). Results SCM thickness and CSA were greatest at the middle injection point (mean +/- SD of 6.6 +/- 2.0 mm and 1.4 +/- 0.6 cm(2), respectively). All injections were successful, except in one case where the SCM was thin and the dye reached the omohyoid muscle. Mean longitudinal dye dispersion and dispersion ratio were significantly greater when the volume was 5 mL. There were no statistically significant differences in dispersion patterns among the three injection points. Conclusions Ultrasound-guided intramuscular injection can be performed with good accuracy in the SCM, as ultrasound can be used to evaluate SCM thickness and CSA. Higher volumes of injection solution appear to diffuse better, but further clinical studies are required to determine optimal injection volume.
Files in This Item
There are no files associated with this item.
Appears in
Collections
1. Basic Science > Department of Anatomy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Joon Shik photo

Yoon, Joon Shik
Guro Hospital (Department of Physical Medicine and Rehabilitation, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE