Detailed Information

Cited 5 time in webofscience Cited 0 time in scopus
Metadata Downloads

Renal tissue elasticity by acoustic radiation force impulse A prospective study of healthy kidney donors

Authors
Lee, AlanJoo, Dong JinHan, Woong KyuJeong, Hyeon JooOh, Min JungKim, Yu SeunOh, Young Taik
Issue Date
22-Jan-2021
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
acoustic radiation force impulse; elastography; intestinal fibrosis; living donor kidney transplantation; normal kidney; shear wave velocity
Citation
MEDICINE, v.100, no.3
Indexed
SCIE
SCOPUS
Journal Title
MEDICINE
Volume
100
Number
3
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/52113
DOI
10.1097/MD.0000000000023561
ISSN
0025-7974
1536-5964
Abstract
Background: Some studies reported the correlations between renal parenchymal stiffness measured by transient elastography or acoustic radiation force impulse (ARFI) and the extent of interstitial fibrosis. This study was prospectively designed to evaluate the correlation between clinical, histological findings and the kidney shear wave velocity (SWV, m/s) assessed by ARFI elastography to identify factors affecting the kidney SWV in normal patients. Methods: Seventy-three adult living kidney transplantation donors were enrolled in our center between September 2010 and January 2013. Before transplantation, all donors were evaluated by ARFI elastography to identify the range of SWV in kidneys. Time-zero biopsies were performed on all graft kidneys before implantation. Results: Mean age of donors was 42.0 +/- 11.3 years. The mean SWV and depth were 2.21 +/- 0.58 m/s and 5.37 +/- 1.06 cm. All histological findings showed mild degree of the Banff score, only grade I. In univariate analyses, the SWV was not associated with all histological parameters. Age (r = -0.274, P = .019) diastolic blood pressure (DBP, r = -0.255, P = .030) and depth for SWV measurement (r = -0.345, P = .003) were significantly correlated with the SWV. In multivariate linear regression analysis, age, gender, body mass index (BMI), and depth for SWV measurement were significantly correlated with the SWV (P = .003, .005, .002, and .004, respectively). Conclusions: We demonstrated that all histological findings are not correlated with the SWV of donor kidney. Otherwise, factors influencing the kidney SWV assessed by ARFI elastography are age, gender, BMI, and depth for the SWV measurement in donors for kidney transplantation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Surgical Critical Care and Trauma Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE