Detailed Information

Cited 9 time in webofscience Cited 0 time in scopus
Metadata Downloads

An Automated Microscopic Malaria Parasite Detection System Using Digital Image Analysis

Authors
Yoon, JungJang, Woong SikNam, JeonghunMihn, Do-CiCLim, Chae Seung
Issue Date
Mar-2021
Publisher
MDPI
Keywords
malaria; microscopy; parasitemia; automation; P. falciparum; P. vivax
Citation
DIAGNOSTICS, v.11, no.3
Indexed
SCIE
SCOPUS
Journal Title
DIAGNOSTICS
Volume
11
Number
3
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/52600
DOI
10.3390/diagnostics11030527
ISSN
2075-4418
2075-4418
Abstract
Rapid diagnosis and parasitemia measurement is crucial for management of malaria. Microscopic examination of peripheral blood (PB) smears is the gold standard for malaria detection. However, this method is labor-intensive. Here, we aimed to develop a completely automated microscopic system for malaria detection and parasitemia measurement. The automated system comprises a microscope, plastic chip, fluorescent dye, and an image analysis program. Analytical performance was evaluated regarding linearity, precision, and limit of detection and was compared with that of conventional microscopic PB smear examination and flow cytometry. The automated microscopic malaria parasite detection system showed a high degree of linearity for Plasmodium falciparum culture (R-2 = 0.958, p = 0.005) and Plasmodium vivax infected samples (R-2 = 0.931, p = 0.008). Precision was defined as the %CV of the assay results at each level of parasitemia and the %CV value for our system was lower than that for microscopic examination for all densities of parasitemia. The limit of detection analysis showed 95% probability for parasite detection was 0.00066112%, and a high correlation was observed among all three methods. The sensitivity and specificity of the system was both 100% (n = 21/21) and 100% (n = 50/50), respectively, and the system correctly identified all P. vivax and P. falciparum samples. The automated microscopic malaria parasite detection system offers several advantages over conventional microscopy for rapid diagnosis and parasite density monitoring of malaria.
Files in This Item
There are no files associated with this item.
Appears in
Collections
4. Research institute > Institute for Trauma Research > 1. Journal Articles
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
Guro Hospital (Department of Laboratory Medicine, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE