Detailed Information

Cited 14 time in webofscience Cited 13 time in scopus
Metadata Downloads

Clinical performance evaluation of the BD Veritor System Flu A plus B assay

Authors
Nam, Myung-HyunJang, Jin WooLee, Jong-HanCho, Chi HyunLim, Chae SeungKim, Woo Joo
Issue Date
Aug-2014
Publisher
ELSEVIER
Keywords
Influenza; Rapid antigen test; Point-of-care; Evaluation; Sensitivity; BD Veritor((TM)) System
Citation
JOURNAL OF VIROLOGICAL METHODS, v.204, pp 86 - 90
Pages
5
Indexed
SCI
SCIE
SCOPUS
Journal Title
JOURNAL OF VIROLOGICAL METHODS
Volume
204
Start Page
86
End Page
90
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/9070
DOI
10.1016/j.jviromet.2014.04.009
ISSN
0166-0934
1879-0984
Abstract
Early identification of influenza is important for optimal patient management and infection control. Rapid influenza antigen tests have been used routinely in clinical settings to confirm clinical suspicion, despite their low sensitivity. To improve sensitivity, various influenza point-of-care test reader systems have been developed. This study evaluated the clinical performance of a digital readout rapid influenza diagnostic test (RIDT), the BD Veritor(Tm) System Flu A + B assay (BD). Nasopharyngeal swabs taken from 250 patients (influenza A positive, n = 75; influenza B positive, n = 75; and influenza negative, n = 100) were analyzed using the BinaxNOW((R)) Influenza A/B antigen kit (BN), SD Influenza Ag A/B kit (SD), BD, real-time reverse transcriptase polymerase chain reaction (RT-PCR), and an influenza virus culture. Compared to RT-PCR, the sensitivities of BN, SD, and BD were 56.0, 53.3, and 72.0%, respectively, for influenza A and 57.3, 65.3, and 69.3%, respectively, for influenza B. No false-positive results were noted with the three rapid antigen tests. For influenza A, the average RT-PCR threshold cycle (Ct) for specimens that tested positive using BD was higher than that for specimens that tested positive using BN and SD. BD is a sensitive and easy method for the early detection of influenza A and B. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Infectious Diseases > 1. Journal Articles
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Woo Joo photo

Kim, Woo Joo
Guro Hospital (Department of Infectious Diseases, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE