Detailed Information

Cited 10 time in webofscience Cited 11 time in scopus
Metadata Downloads

Efficacy of Hemocontrol Biofeedback System in Intradialytic Hypotension-Prone Hemodialysis Patients

Full metadata record
DC Field Value Language
dc.contributor.authorGil, Hyo-Wook-
dc.contributor.authorBang, Kitae-
dc.contributor.authorLee, So Young-
dc.contributor.authorHan, Byoung Geun-
dc.contributor.authorKim, Jin Kuk-
dc.contributor.authorKim, Young Ok-
dc.contributor.authorSong, Ho Cheol-
dc.contributor.authorKwon, Young Joo-
dc.contributor.authorKim, Yong-Soo-
dc.date.available2020-11-02T18:42:44Z-
dc.date.issued2014-06-
dc.identifier.issn1011-8934-
dc.identifier.issn1598-6357-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/9254-
dc.description.abstractWe conducted a study to determine whether the hemocontrol biofeedback system (HBS) can improve intradialytic hypotension (IDH) in hypotension-prone hemodialysis (HD) patients compared with conventional HD. In this multicenter prospective crossover study, 60 hypotension-prone patients were serially treated by conventional HD for 8 weeks (period A), by HD with hemoscan blood volume monitoring for 2 weeks (period B0), and by HBS HD for 8 weeks (period B1). The number of sessions complicated by symptomatic IDH during 24 HD sessions (14.9 +/- 5.8 sessions, 62.1% in period A vs 9.2 +/- 7.2 sessions, 38.4% in period B1, P < 0.001) and the number of IDH-related nursing interventions in a session (0.96 +/- 0.66 in period A vs 0.56 +/- 0.54 in period B1, P < 0.001) significantly decreased in period B1 than in period A. Recovery time from fatigue after dialysis was significantly shorter in period B1 than in period A. The patients with higher post-dialysis blood pressure, lower difference between pre- and post-dialysis blood pressure, less frequent IDH, and higher pre- and post-dialysis body weight in period A responded better to HBS in period B1 in regard to the reduction of IDH. In conclusion, HBS may improve the patient tolerability to HD by reducing the IDH frequency and promoting faster recovery from fatigue after dialysis.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN ACAD MEDICAL SCIENCES-
dc.titleEfficacy of Hemocontrol Biofeedback System in Intradialytic Hypotension-Prone Hemodialysis Patients-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3346/jkms.2014.29.6.805-
dc.identifier.scopusid2-s2.0-84925226276-
dc.identifier.wosid000337339300011-
dc.identifier.bibliographicCitationJOURNAL OF KOREAN MEDICAL SCIENCE, v.29, no.6, pp 805 - 810-
dc.citation.titleJOURNAL OF KOREAN MEDICAL SCIENCE-
dc.citation.volume29-
dc.citation.number6-
dc.citation.startPage805-
dc.citation.endPage810-
dc.type.docTypeArticle-
dc.identifier.kciidART001881501-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusIMPACT-
dc.subject.keywordPlusULTRAFILTRATION-
dc.subject.keywordPlusPREVENTION-
dc.subject.keywordPlusSTABILITY-
dc.subject.keywordPlusMORTALITY-
dc.subject.keywordAuthorHypotension-
dc.subject.keywordAuthorRenal Dialysis-
dc.subject.keywordAuthorClinical Trial-
dc.subject.keywordAuthorDialysis Volume-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Nephrology and Hypertension > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwon, Young Joo photo

Kwon, Young Joo
Guro Hospital (Department of Nephrology and Hypertension, Guro Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE