Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Optimization of Beam Orientation and Virtual Organ Delineation for Lung IMRT

Authors
Chang, Kyung HwanLee, SukCao, Yuan JieShim, Jang BoLee, Ji EunLee, Jung AeYang, Dae SikPark, Young JeYoon, Won SupKim, Chul YongCho, Sam JuLee, Sang HoonKim, Woo ChulMin, Chul KeeCho, Kwang HwanDo Huh, Hyun
Issue Date
Apr-2014
Publisher
한국물리학회
Keywords
IMRT; Virtual organ delineation (VOD); Optimization; Lung cancer
Citation
Journal of the Korean Physical Society, v.64, no.7, pp 1047 - 1054
Pages
8
Indexed
SCI
SCIE
SCOPUS
KCI
Journal Title
Journal of the Korean Physical Society
Volume
64
Number
7
Start Page
1047
End Page
1054
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/9425
DOI
10.3938/jkps.64.1047
ISSN
0374-4884
1976-8524
Abstract
This study demonstrates the feasibility of the proposed intensity-modulated radiotherapy (IMRT) techniques for minimizing the dose to the lungs and organs at risk (OARs) for variations in the number of beams, the orientations of the beams, the virtual organ delineation (VOD) position, the VOD size and the dose constraints in order to optimize the treatment plan for lung cancer. We used 5, 7, 9 and 14 equiangularly-spaced beams and 7 and 9 non-equiangularly-spaced beams. We measured the volume of the lungs receiving at least 20 Gy and 25 Gy (V-20 and V-25) for variations in the orientations of the beams, the VOD position, and the size of the tumor and the contra-lateral lung. For the tumor and the contra-lateral lung, the V-20 and the V-25 values of 14 equiangularly-spaced ports were slightly lower than those of other equiangularly-spaced beam orientations. For non-equiangularly-spaced beam orientations, the lowest V-20 and V-25 values in the tumor and the contral-lateral lung were recorded in ports 7, and 9, respectively. For tumors of the lung, the average values of 7 non-equiangularly-spaced ports were lower than those for 14 equiangularly-spaced ports. The values of V-20 and V-25 for variations in the VOD size and the VOD position showed no significant differences for the lung tumor of patient 1 when the dose constraint of the VOD was 10, 25 and 30 Gy. For the lung tumor, the values of V-20 and V-25 for various VOD sizes and positions ranged from 15 to 37% in patient 2 and from 28 to 45% in patient 3. The values of V-20 and V-25 were within 7% for the contra-lateral lung of patient 1. For patient 2, the values of V-20 and V-25 ranged from 7 to 18%. For the contra-lateral lung of patient 3, the V-20 and V-25 values ranged from 12 to 25%. IMRT techniques with various VOD and beam orientations are important for determine in treatment plans.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Young Je photo

Park, Young Je
Anam Hospital (Department of Radiation Oncology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE