Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Automated machine learning (AutoML)-based surface registration methodology for image-guided surgical navigation system

Authors
Yoo, HakjeSim, Taeyong
Issue Date
Jul-2022
Publisher
American Association of Physicists in Medicine
Keywords
automated machine learning; Bayesian optimization; image-guided surgery; iterative closest point; surface registration
Citation
Medical Physics, v.49, no.7, pp 4845 - 4860
Pages
16
Indexed
SCIE
SCOPUS
Journal Title
Medical Physics
Volume
49
Number
7
Start Page
4845
End Page
4860
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/61023
DOI
10.1002/mp.15696
ISSN
0094-2405
2473-4209
Abstract
Background Although the surface registration technique has the advantage of being relatively safe and the operation time is short, it generally has the disadvantage of low accuracy. Purpose This research proposes automated machine learning (AutoML)-based surface registration to improve the accuracy of image-guided surgical navigation systems. Methods The state-of-the-art surface registration concept is that first, using a neural network model, a new point-cloud that matches the facial information acquired by a passive probe of an optical tracking system (OTS) is extracted from the facial information obtained by computerized tomography. Target registration error (TRE) representing the accuracy of surface registration is then calculated by applying the iterative closest point (ICP) algorithm to the newly extracted point-cloud and OTS information. In this process, the hyperparameters used in the neural network model and ICP algorithm are automatically optimized using Bayesian optimization with expected improvement to yield improved registration accuracy. Results Using the proposed surface registration methodology, the average TRE for the targets located in the sinus space and nasal cavity of the soft phantoms is 0.939 ± 0.375 mm, which shows 57.8% improvement compared to the average TRE of 2.227 ± 0.193 mm calculated by the conventional surface registration method (p < 0.01). The performance of the proposed methodology is evaluated, and the average TREs computed by the proposed methodology and the conventional method are 0.767 ± 0.132 and 2.615 ± 0.378 mm, respectively. Additionally, for one healthy adult, the clinical applicability of the AutoML-based surface registration is also presented. Conclusion Our findings showed that the registration accuracy could be improved while maintaining the advantages of the surface registration technique.
Files in This Item
There are no files associated with this item.
Appears in
Collections
4. Research institute > Medical Big-data Research Center > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE