Detailed Information

Cited 4 time in webofscience Cited 5 time in scopus
Metadata Downloads

Artificial Intelligence-Based Identification of Normal Chest Radiographs: A Simulation Study in a Multicenter Health Screening Cohort

Authors
Yoo, HyunsukKim, Eun YoungKim, HyungjinChoi, Ye RaKim, Moon YoungHwang, Sung HoKim, Young JoongCho, Young JunJin, Kwang Nam
Issue Date
Oct-2022
Publisher
대한영상의학회
Keywords
Artificial intelligence; Chest radiograph; Screening; Lung cancer; Normal triage
Citation
Korean Journal of Radiology, v.23, no.10, pp 1009 - 1018
Pages
10
Indexed
SCIE
SCOPUS
KCI
Journal Title
Korean Journal of Radiology
Volume
23
Number
10
Start Page
1009
End Page
1018
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/61739
DOI
10.3348/kjr.2022.0189
ISSN
1229-6929
2005-8330
Abstract
Objective This study aimed to investigate the feasibility of using artificial intelligence (AI) to identify normal chest radiography (CXR) from the worklist of radiologists in a health-screening environment. Materials and Methods This retrospective simulation study was conducted using the CXRs of 5887 adults (mean age ± standard deviation, 55.4 ± 11.8 years; male, 4329) from three health screening centers in South Korea using a commercial AI (Lunit INSIGHT CXR3, version 3.5.8.8). Three board-certified thoracic radiologists reviewed CXR images for referable thoracic abnormalities and grouped the images into those with visible referable abnormalities (identified as abnormal by at least one reader) and those with clearly visible referable abnormalities (identified as abnormal by at least two readers). With AI-based simulated exclusion of normal CXR images, the percentages of normal images sorted and abnormal images erroneously removed were analyzed. Additionally, in a random subsample of 480 patients, the ability to identify visible referable abnormalities was compared among AI-unassisted reading (i.e., all images read by human readers without AI), AI-assisted reading (i.e., all images read by human readers with AI assistance as concurrent readers), and reading with AI triage (i.e., human reading of only those rendered abnormal by AI). Results Of 5887 CXR images, 405 (6.9%) and 227 (3.9%) contained visible and clearly visible abnormalities, respectively. With AI-based triage, 42.9% (2354/5482) of normal CXR images were removed at the cost of erroneous removal of 3.5% (14/405) and 1.8% (4/227) of CXR images with visible and clearly visible abnormalities, respectively. In the diagnostic performance study, AI triage removed 41.6% (188/452) of normal images from the worklist without missing visible abnormalities and increased the specificity for some readers without decreasing sensitivity. Conclusion This study suggests the feasibility of sorting and removing normal CXRs using AI with a tailored cut-off to increase efficiency and reduce the workload of radiologists.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Sung Ho photo

Hwang, Sung Ho
Anam Hospital (Department of Radiology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE