Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Real-World Comparison of Transcatheter Versus Surgical Aortic Valve Replacement in the Era of Current-Generation Devicesopen access

Authors
Sa, Young KyoungHwang, Byung-HeeChung, Woo-BaekLee, Kwan YongLee, JungkukKang, DongwooKo, Young-GukYu, Cheol WoongKim, JuhanChoi, Seung-HyukBae, Jang-WhanChae, In-HoChoi, Yun-SeokPark, Chul SooYoo, Ki DongJeon, Doo SooKim, Hyo-SooChung, Wook-SungChang, Kiyuk
Issue Date
Jan-2023
Publisher
MDPI AG
Keywords
aortic stenosis; transcatheter aortic valve replacement; surgical aortic valve replacement; mortality
Citation
Journal of Clinical Medicine, v.12, no.2
Indexed
SCIE
SCOPUS
Journal Title
Journal of Clinical Medicine
Volume
12
Number
2
URI
https://scholarworks.korea.ac.kr/kumedicine/handle/2021.sw.kumedicine/62382
DOI
10.3390/jcm12020571
ISSN
2077-0383
Abstract
Few studies have reported comparisons of out-of-hospital clinical outcomes after transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis (AS) in the era of current-generation valves that reflect the real-world situation. Data on patients with severe AS aged 65 years or older who underwent TAVR or SAVR between 2015 and 2018 were obtained from the National Health Insurance Service in Korea and clinical event rate was analyzed. The primary endpoint was all-cause death at 1 year. The cohort included a total of 4623 patients over 65 years of age, of whom 1269 (27.4%) were treated with TAVR. After 1:1 propensity score matching, 2120 patients were included in the study. TAVR was associated with reduced 1-year mortality (hazard ratio (HR): 0.55; 95% confidence interval (CI): 0.42-0.70; p < 0.001). There was no difference between the groups in the incidence of ischemic stroke (HR: 0.72, 95% CI: 0.43-1.20; p = 0.21) and intracranial hemorrhage (HR: 1.10; p = 0.74). Permanent pacemaker insertion was observed more frequently in the TAVR cohort (9.4% vs. 2.5%, HR: 3.95, 95% CI: 2.57-6.09; p < 0.001), whereas repeat procedures were rare in both treatments (0.5% vs. 0.3%, p = 0.499). In the nation-wide real-world data analysis, TAVR with current-generation devices showed significantly lower 1-year mortality compared to SAVR in severe AS patients.
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Cardiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yu, Cheol Woong photo

Yu, Cheol Woong
Anam Hospital (Department of Cardiology, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE