상세 보기
Evaluation of 99mTc-mercaptoacetyltriglycine-biocytin as a new hepatobiliary imaging agent in mice coinjected with bilirubin
- Kim M.-K.;
- Seidel J.;
- Le N.;
- Kim I.-S.;
- Yoo T.-M.;
- 외 5명
SCOPUS
5초록
We evaluated 99mTc-labeled mercaptoacetyltriglycine (99m)Tc- MAG3)-biocytin as a hepatobiliary imaging agent in the absence and presence of bilirubin in mice. We then compared its pharmacokinetic parameters; peak liver/heart activity ratio (r(max)) and half clearance time (HCT) with those of (99mTc-labeled diisopropyl-iminodiacetic acid (99mTc-disofenin). Balb/c mice were injected intravenously with hepatobiliary agent (99mTc- MAG3-biocytin or 99mTc-disofenin) alone or in combination with bilirubin at two doses (7 and 14 mg/kg) dissolved in 5% human serum albumin. Images were acquired every 15 s for 30 min with a gamma-camera equipped with a pinhole collimator. Dynamic images showed rapid hepatic uptake of 99mTc- MAG3-biocytin, with rapid clearance from the blood and rapid excretion via the biliary system. Its hepatic uptake was not affected by bilirubin coinjection, whereas 99mTc-disofenin coinjected with bilirubin showed a higher blood background than 99mTc-disofenin alone. These qualitative findings were reflected in pharmacokinetic parameters, r(max) and HCT. The r(max) was obtained from plots of time versus liver/heart activity ratios obtained in equal-area regions of interest over the heart and liver. The HCT was calculated from the hepatic clearance curve from plots of time versus liver activity. 99mTc-MAG3-biocytin without bilirubin coinjection showed an r(max) of 8.9 ± 1.3 and an HCT of 399 ± 36 s. These values did not change even when 14 mg/kg of bilirubin were coinjected. By contrast, the parameters for 99mTc-disofenin with bilirubin were significantly (p < 0.01) affected by 14 mg/kg of bilirubin coinjection: r(max) was decreased from 7.9 ± 2.5 to 1.4 ± 0.2 and HCT was increased from 292 ± 32 s to 782 ± 133 s. 99mTc-MAG3-biocytin hepatobiliary scintigraphy in mice is not affected by bilirubin coinjection, and this hepatobiliary agent appears to offer promise for estimating hepatic function in patients with high bilirubin levels.
키워드
- 제목
- Evaluation of 99mTc-mercaptoacetyltriglycine-biocytin as a new hepatobiliary imaging agent in mice coinjected with bilirubin
- 저자
- Kim M.-K.; Seidel J.; Le N.; Kim I.-S.; Yoo T.-M.; Barker C.; Kobayashi H.; Green M.V.; Carrasquillo J.A.; Paik C.H.
- 발행일
- 1999
- 유형
- Article
- 권
- 26
- 호
- 1
- 페이지
- 43 ~ 49
- 언어
- ENG
- 발행국가
- 미국
- 분량
- 7 페이지
- ISSN
- E 1872-9614
P 0969-8051