Background To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Methods Two thousand samples of corneal parameters with keratometric astigmatism >= 1.0 D were obtained using boot-strap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. Results The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. Conclusions The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.

키워드

Toric intraocular lens; Posterior corneal astigmatism; Incision-induced astigmatism; Effective lens position; ANTERIOR-CHAMBER DEPTH; SURGICALLY INDUCED ASTIGMATISM; POWER CALCULATION; ROTATIONAL STABILITY; PSEUDOPHAKIC EYES; HAIGIS FORMULAS; CYLINDER POWER; HOFFER-Q; SRK/T; IMPLANTATION
제목
Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
저자
Eom, Youngsub; Ryu, Dongok; Kim, Dae Wook; Yang, Seul Ki; Song, Jong Suk; Kim, Sug-Whan; Kim, Hyo Myung
DOI
10.1007/s00417-016-3446-3
발행일
2016-10
유형
Article
저널명
Graefe's Archive for Clinical and Experimental Ophthalmology
권
254
호
10
페이지
1977 ~ 1986