상세 보기
Brain Oxygen Monitoring via Jugular Venous Oxygen Saturation in a Patient with Fulminant Hepatic Failure
- 김예림;
- 김치경;
- Seunguk Jung;
- Sang-Bae Ko
초록
Fulminant hepatic failure (FHF) is often accompanied by a myriad of neurologic complications, which are associated with high morbidity and mortality. Although appropriate neuromonitoring is recommended for early diagnosis and to minimize secondary brain injury, individuals with FHF usually have a high chance of coagulopathy, which limits the ability to use invasive neuromonitoring. Jugular bulb venous oxygen saturation (JvO2) monitoring is well known as a surrogate direct measures of global brain oxygen use. We report the case of a patient with increased intracranial pressure due to FHF, in which JvO2 was used for appropriate brain oxygen monitoring.
키워드
brain edema; liver failure; acute; hepatic encephalopathy; jugular vein; oxygen consumption.
- 제목
- Brain Oxygen Monitoring via Jugular Venous Oxygen Saturation in a Patient with Fulminant Hepatic Failure
- 저자
- 김예림; 김치경; Seunguk Jung; Sang-Bae Ko
- 발행일
- 2016-08
- 권
- 31
- 호
- 3
- 페이지
- 251 ~ 255
- 언어
- ENG
- 출판사
- 대한중환자의학회
- 발행국가
- 대한민국
- 분량
- 5 페이지
- ISSN
- E 2586-6060
P 2586-6052