Usefulness of a Vascular Clipping System to Create an Arteriovenous Fistula

초록

Purpose The vascular clipping system (VCS) is beneficial as it is simple and easy to apply for microvascular suturing. Arteriovenous fistula (AVF) creation is a very basic standard technique of microvascular surgery. In this study the VCS and the conventional suture methods were compared in a rabbit model using the carotid artery and vein to create an AVF. Methods There were 28 rabbits assigned equally into 2 groups using the AVF creation method (conventional suturing or the VCS procedure). Histopathology was performed on fixed samples. The procedure time of the 2 methods and changes in histopathology of tissue samples after surgery were compared. Results The VCS procedure showed a lower degree of fibrosis and hyperplasia histologically compared with the conventional suture method. The VCS was quicker to perform and no significant anastomosis stricture was observed. Conclusion In a rabbit model of AVF, the VCS has benefits over the conventional suture method. The VCS provides comparable patency rates, produces fewer side effects such as fibrosis and hyperplasia, and takes less operation time than suturing. The VCS is expected to be useful for cases where renal patients need periodic hemodialysis and thus repetitive access to a vessel.

키워드

arteriovenous fistula
제목
Usefulness of a Vascular Clipping System to Create an Arteriovenous Fistula
저자
Lee, Jin Suk; Nam, Kuk Jin; Yoon, Sam Youl; Lee, Kun Ok; Han, Hyung Joon; Cho, Sung Jin; Park, Jong Woong; Song, Tae jin
DOI
10.17479/jacs.2020.10.3.101
발행일
2020-11
유형
Article
저널명
Journal of Acute Care Surgery
권
10
호
3
페이지
101 ~ 105