상세 보기
초록
We report four cases in which a pericardium (Tutoplast) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12-26 months). The pericardium (Tutoplast) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants.
키워드
- 제목
- Pericardium plug in the repair of the corneoscleral fistula after Ahmed Glaucoma Valve explantation.
- 저자
- Yoo C.; Kwon S.W.; Kim Y.Y.
- 발행일
- 2008
- 유형
- Article
- 권
- 22
- 호
- 4
- 페이지
- 268 ~ 271
- 언어
- ENG
- 출판사
- 대한안과학회
- 발행국가
- 대한민국
- 분량
- 4 페이지
- ISSN
- E 2092-9382
P 1011-8942