상세 보기
Comparison of prostate-specific antigen adjusted for transition zone volume versus prostate-specific antigen density in predicting prostate cancer by transrectal ultrasonography
WEB OF SCIENCE
6SCOPUS
9초록
Objective. Prostate-specific antigen is an excellent tumor marker, but it is not specific for prostate cancer. We evaluated the efficacy of prostate-specific antigen adjusted for transition zone volume calculated by transrectal ultrasonography in predicting prostate cancer in men with intermediate prostate-specific antigen levels of 4.1 to 10.0 ng/mL compared with prostate-specific antigen density. Methods. Between June 1998 and December 2001, prostate-specific antigen adjusted for transition zone volume was obtained from 131 patients who underwent ultrasonographically guided biopsies and had prostate-specific antigen of 4.1 to 10.0 ng/mL. Prostate-specific antigen density was calculated by dividing total serum prostate-specific antigen by total prostate volume, and total serum prostate-specific antigen was divided by transition zone volume to yield prostate-specific antigen adjusted for transition zone volume. This was compared with prostate-specific antigen density via receiver operating characteristic curves. Results. Of 131 patients, 34 (26%) had prostate cancer, and 97 (74%) had benign prostatic hyperplasia on pathologic examination. Total prostate volume was correlated with transition zone volume (P < 001) Mean prostate-specific antigen adjusted for transition zone volume and prostate-specific antigen density were 0.71 +/- 0.25 and 0.27 +/- 0.09 ng (.) mL(-1) (.) mL(-1) in patients with prostate cancer and 0.32 +/- 0.09 and 0.16 +/- 0.05 ng (.) mL(-1) (.) mL(-1) in patients with benign prostatic hyperplasia. With a cutoff value of 0.35 ng (.) mL(-1) (.) mL(-1), prostate-specific antigen adjusted for transition zone volume had sensitivity of 82% and specificity of 84%. Receiver operating characteristic curve analysis showed that prostate-specific antigen adjusted for transition zone volume predicted biopsy outcome significantly better than prostate-specific antigen density (P < .05). Conclusions. Prostate-specific antigen adjusted for transition zone volume is more accurate than prostate-specific antigen density in distinguishing prostate cancer from benign prostatic hyperplasia in men with intermediate serum prostate-specific antigen of 4.1 to 10.0 ng/mL. Determination of transition zone volume by transrectal ultrasonography may be helpful for predicting the probability of positive biopsy results.
키워드
- 제목
- Comparison of prostate-specific antigen adjusted for transition zone volume versus prostate-specific antigen density in predicting prostate cancer by transrectal ultrasonography
- 저자
- Sung, DJ; Cho, SB; Kim, YH; Oh, YW; Lee, NJ; Kim, JH; Chung, KB; Moon, DG
- 발행일
- 2004-05
- 유형
- Article
- 권
- 23
- 호
- 5
- 페이지
- 615 ~ 622
- 언어
- ENG
- 출판사
- American Institute for Ultrasound in Medicine
- 발행국가
- 미국
- 분량
- 8 페이지
- ISSN
- E 1550-9613
P 0278-4297