Cerebral Blood Volume Analysis in Glioblastomas Using Dynamic Susceptibility Contrast-Enhanced Perfusion MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

  • Jung S.C.; 
  • Choi S.H.; 
  • Yeom J.A.; 
  • Kim J.-H.; 
  • Ryoo I.; 
  • 외 7명
Citations

SCOPUS

44

초록

Purpose:To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.Materials and Methods:Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.Results:Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74-0.89 and CV of 20.39-36.83% in manual segmentation method, and ICC of 0.95-0.99 and CV of 8.53-16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86-0.94 and CV of 19.67-35.15% in manual segmentation method, and ICC of 0.74-1.0 and CV of 5.48-49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.Conclusion:The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas. © 2013 Jung et al.

키워드

gadobutrol; contrast medium; adult; aged; article; brain blood flow; cancer grading; clinical article; controlled study; correlation coefficient; female; glioblastoma; histopathology; human; human tissue; image analysis; intermethod comparison; interobserver reproducibility; intraobserver reproducibility; male; manual segmentation method; neuroimaging; nuclear magnetic resonance scanner; quantitative study; reliability; reproducibility; retrospective study; semiautomatic segmentation method; susceptibility weighted imaging; tumor volume; blood volume; brain; brain tumor; comparative study; diagnostic use; glioblastoma; middle aged; nuclear magnetic resonance imaging; pathology; pathophysiology; procedures; vascularization; young adult; Adult; Aged; Blood Volume; Brain; Brain Neoplasms; Contrast Media; Female; Glioblastoma; Humans; Magnetic Resonance Imaging; Male; Middle Aged; Reproducibility of Results; Retrospective Studies; Young Adult; Blood Volume; Brain Neoplasms; Cerebrovascular Circulation; Cluster Analysis; Contrast Media; DNA Methylation; Female; Glioblastoma; Humans; Magnetic Resonance Imaging; Male; Middle Aged; O(6)-Methylguanine-DNA Methyltransferase; Perfusion; Promoter Regions, Genetic; PTEN Phosphohydrolase; Receptor, Epidermal Growth Factor; Regression Analysis; Tumor Suppressor Protein p53
제목
Cerebral Blood Volume Analysis in Glioblastomas Using Dynamic Susceptibility Contrast-Enhanced Perfusion MRI: A Comparison of Manual and Semiautomatic Segmentation Methods
저자
Jung S.C.; Choi S.H.; Yeom J.A.; Kim J.-H.; Ryoo I.; Kim S.C.; Shin H.; Lee A.L.; Yun T.J.; Park C.-K.; Sohn C.-H.; Park S.-H.
DOI
10.1371/journal.pone.0069323
발행일
2013
유형
Article
저널명
PLoS One
권
8
호
8