Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness

  • Lee J.-H.; 
  • Kim J.-T.; 
  • Yoon S.Z.; 
  • Lim Y.-J.; 
  • Jeon Y.; 
  • 외 2명
Citations

SCOPUS

96

초록

Background. Corrected flow time (FTc) by oesophageal Doppler is considered to be a 'static' preload index. We evaluated the ability of FTc to predict fluid responsiveness and compared this with the abilities of other preload indices, such as pulse pressure variation (PPV), central venous pressure (CVP), and left ventricular end-diastolic area index (LVEDAI). Methods. Twenty neurosurgical patients were studied. After induction of anaesthesia, FTc, PPV, LVEDAI, CVP, and stroke volume index (SVI) were measured before and 12 min after fluid loading with 6% hydroxyethyl starch solution (7 ml kg-1). Responders and non-responders were defined as those patients with an SVI increase ≥10% or <10% after fluid loading, respectively. Pearson's correlation was used to assess correlations between changes in SVI and initial haemodynamic variables. Receiver operating characteristic (ROC) curves were constructed and compared to evaluate the overall performance of preload indices (FTc, PPV, LVEDAI, and CVP) in terms of predicting fluid responsiveness. Results. FTc and PPV before fluid loading differed between responders (n = 11) and non-responders (n = 9), and correlated with changes in SVI (r = -0.515 and r = 0.696, respectively), which was opposite to that observed for CVP or LVEDAI. Areas under ROC curves for FTc [0.944 (SD 0.058)] and PPV [0.909 (0.069)] were significantly greater than those for CVP [0.540 (0.133), P < 0.001] and LVEDAI [0.495 (0.133), P < 0.001]. The optimal threshold value given by ROC analysis was 357 ms for FTc. Conclusions. In this study, FTc predicted fluid responsiveness. However, FTc should be used in conjunction with other clinical information. © The Board of Management and Trustees of the British Journal of Anaesthesia 2007. All rights reserved.

키워드

Cardiac output; Fluid balance; Heart; Monitoring, arterial pressure; Monitoring, cardiopulmonary; Monitoring, intraoperative; hetastarch; adult; anesthesia induction; area under the curve; article; central venous pressure; clinical article; correlation coefficient; Doppler flowmeter; Doppler flowmetry; female; flow measurement; fluid flow; fluid retention; heart left ventricle enddiastolic pressure; heart preload; heart stroke volume; human; male; neurosurgery; priority journal; pulse pressure; receiver operating characteristic; standardization; transesophageal echocardiography
제목
Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
저자
Lee J.-H.; Kim J.-T.; Yoon S.Z.; Lim Y.-J.; Jeon Y.; Bahk J.-H.; Kim C.S.
DOI
10.1093/bja/aem179
발행일
2007
유형
Article
저널명
British Journal of Anaesthesia
권
99
호
3
페이지
343 ~ 348