Polyamine dendrimer-based MRI contrast agents for functional kidney imaging to diagnose acute renal failure

  • Kobayashi H.; 
  • Jo S.-K.; 
  • Kawamoto S.; 
  • Yasuda H.; 
  • Hu X.; 
  • 외 4명
Citations

SCOPUS

83

초록

Purpose: To choose an efficacious renal functional MRI contrast agent to image early renal tubular damage. We synthesized and compared smaller polyamine dendrimer-based MRI contrast agents (<60 kD) that, unlike Gd-[DTPA], transiently accumulate in renal tubules and can be used to visualize renal structural and functional damage. Materials and Methods: Six dendrimer-based MRI contrast agents smaller than 60 kD were studied by high resolution dynamic micro-MRI and compared to Gd-[DTPA]-dimeglumine and Gadomer-17. The best agent, DAB-G2, was further tested in a mouse ischemia/reperfusion model to validate its efficacy. Results: Despite unequal renal clearance rates, all polyamine dendrimer agents visualized the renal functional anatomy of the mice better than Gd-[DTPA]-dimeglumine and Gadomer-17. DAB-G2 was excreted most rapidly, yet was able to visualize mild renal tubular injury very early after injury. Conclusion: DAB-G2 was found to be the best candidate for functional kidney imaging and enabled early diagnosis of acute renal injury.

키워드

Acute renal failure; Contrast media; Kidney; Magnetic resonance imaging; Polyamine dendrimer; contrast medium; dendrimer; gadolinium pentetate meglumine; gadomer 17; polyamidoamine; polyamine derivative; polypropylenimine dotriacontamine dendrimer; polypropylenimine hexadecaamine dendrimer; polypropylenimine tetrahexacontaamine dendrimer; unclassified drug; acute kidney failure; animal experiment; animal model; animal tissue; article; contrast enhancement; controlled study; diagnostic imaging; drug clearance; drug determination; drug screening; drug synthesis; dynamics; kidney clearance; kidney function; kidney ischemia; mouse; nonhuman; nuclear magnetic resonance imaging; optical resolution; particle size; priority journal; reperfusion injury; validation process; Analysis of Variance; Animals; Contrast Media; Gadolinium DTPA; Kidney Failure, Acute; Magnetic Resonance Imaging; Mice; Polyamines
제목
Polyamine dendrimer-based MRI contrast agents for functional kidney imaging to diagnose acute renal failure
저자
Kobayashi H.; Jo S.-K.; Kawamoto S.; Yasuda H.; Hu X.; Knopp M.V.; Brechbiel M.W.; Choyke P.L.; Star R.A.
DOI
10.1002/jmri.20147
발행일
2004
유형
Article
저널명
Journal of Magnetic Resonance Imaging
권
20
호
3
페이지
512 ~ 518