A surface-tension driven micropump for low-voltage and low-power operations

  • Yun, Kwang-Seok; 
  • Cho, Il-Joo; 
  • Bu, Jong-Uk; 
  • Kim, Chang-Jin; 
  • Yoon, Euisik
Citations

WEB OF SCIENCE

140
Citations

SCOPUS

156

초록

In this paper, we first report a micropump actuated by surface tension based on continuous electrowetting (CEW). We have used the surface-tension-induced motion of a mercury drop in a microchannel filled with an electrolyte as actuation energy for the micropump. This allows low voltage operation as well as low-power consumption. The micropump is composed of a stack of three wafers bonded together. The microchannel is formed on a glass wafer using SU-8 and is filled with electrolyte where the mercury drop is inserted. The movement of the mercury pushes or drags the electrolyte, resulting in the deflection of a membrane that is formed on the second silicon wafer. Another silicon wafer, which has passive check valves and holes, is stacked on the membrane wafer, forming inlet and outlet chambers. Finally, these two chambers are connected through a silicone tube forming the complete micropump. The performance of the fabricated micropump has been tested for various operation voltages and frequencies. We have demonstrated actual liquid pumping up to 70 mul/min with a driving voltage of 2.3 V and a power consumption of 170 muW. The maximum pump pressure is about 800 Pa at the applied voltage of 2.3 V with an operation frequency of 25 Hz.

키워드

continuous electrowetting; liquid metal; low power; low voltage; microfluidics; micropump; surface tension; THERMOPNEUMATIC MICROPUMP; SYSTEMS
제목
A surface-tension driven micropump for low-voltage and low-power operations
저자
Yun, Kwang-Seok; Cho, Il-Joo; Bu, Jong-Uk; Kim, Chang-Jin; Yoon, Euisik
DOI
10.1109/JMEMS.2002.803286
발행일
2002-10
유형
Article
저널명
Journal of Microelectromechanical Systems
권
11
호
5
페이지
454 ~ 461