Durable polymer versus biodegradable polymer drug-eluting stents in patients with acute coronary syndrome undergoing complex percutaneous coronary intervention: a post hoc analysis of the HOST-REDUCE-POLYTECH-ACS trial

  • Hwang, Doyeon; 
  • Lim, Hong-Seok; 
  • Park, Kyung Woo; 
  • Shin, Won -Yong; 
  • Kang, Jeehoon; 
  • ... Hong, Soon Jun; 
  • 외 13명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Background Comparative data of durable polymer (DP) versus biodegradable polymer (BP) drug-eluting stents (DES) are limited in patients presenting with acute coronary syndrome (ACS) undergoing complex percutaneous coronary intervention (PCI). Aims We sought to evaluate the efficacy and safety of DP-DES and BP-DES in ACS patients receiving complex PCI. Methods This study was a post hoc analysis of the HOST-REDUCE-POLYTECH-ACS trial. ACS patients were randomly assigned 1:1 to DP-DES or BP-DES in the HOST-REDUCE-POLYTECH-ACS trial. Complex PCI was defined as having at least 1 of the following features: ≥3 stents implanted, ≥3 lesions treated, total stent length ≥60 mm, bifurcation PCI with 2 stents, left main PCI, or heavy calcification. Patient-oriented (POCO, a composite of all-cause death, non-fatal myocardial infarction, and any repeat revascularisation) and device-oriented composite outcomes (DOCO, a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularisation) were evaluated at 12 months. Results Among 3,301 patients for whom full procedural data were available, 1,140 patients received complex PCI. Complex PCI was associated with higher risks of POCO and DOCO. The risks of POCO were comparable between DP-DES and BP-DES in both the complex (HR 0.87, 95% confidence interval [CI]: 0.57-1.33; p=0.522) and non-complex (HR 0.83, 95% CI: 0.56-1.24; p=0.368; p for interaction=0.884) PCI groups. DOCO was also not significantly different between DP-DES and BP-DES in both the complex (HR 0.74, 95% CI: 0.43-1.27; p=0.278) and non-complex (HR 0.67, 95% CI: 0.38-1.19; p=0.175; p for interaction=0.814) PCI groups. Conclusions In ACS patients, DP-DES and BP-DES showed similar clinical outcomes irrespective of PCI complexity.

키워드

ACS; NSTE-ACS; clinical research; clinical trials; drug-eluting stent; ARTERY-DISEASE; ANTIPLATELET THERAPY; THIN-STRUT; THROMBOSIS; OUTCOMES; REVASCULARIZATION; DESIGN; RISK
제목
Durable polymer versus biodegradable polymer drug-eluting stents in patients with acute coronary syndrome undergoing complex percutaneous coronary intervention: a post hoc analysis of the HOST-REDUCE-POLYTECH-ACS trial
저자
Hwang, Doyeon; Lim, Hong-Seok; Park, Kyung Woo; Shin, Won -Yong; Kang, Jeehoon; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon -Kwon; Cho, Yun-Kyeong; Hong, Soon Jun; Kim, Sanghyun; Jo, Sang -Ho; Kim, Yong Hoon; Kim, Weon; Lee, Sung Yun; Oh, Seok Kyu; Kim, Dong-Bin; Kim, Hyo-Soo
DOI
10.4244/EIJ-D-22-00372
발행일
2022-12
유형
Article
저널명
EuroIntervention
권
18
호
11
페이지
e910 ~ e919