상세 보기
Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
- Lee, Dong Ho;
- Lee, Jeong Min;
- Lee, Chang Hee;
- Afat, Saif;
- Othman, Ahmed
WEB OF SCIENCE
23SCOPUS
28초록
Purpose: To compare the image quality and diagnostic capability in detecting malignant liver tumors of low-dose CT (LDCT, 33% dose) with deep learning-based denoising (DLD) and standard-dose CT (SDCT, 100% dose) with model-based iterative reconstruction (MBIR). Materials and Methods: In this prospective, multicenter, noninferiority study, individuals referred for liver CT scans were enrolled from three tertiary referral hospitals between February 2021 and August 2022. All liver CT scans were conducted using a dual-source scanner with the dose split into tubes A (67% dose) and B (33% dose). Blended images from tubes A and B were created using MBIR to produce SDCT images, whereas LDCT images used data from tube B and were reconstructed with DLD. The noise in liver images was measured and compared between imaging techniques. The diagnostic performance of each technique in detecting malignant liver tumors was evaluated by three independent radiologists using jackknife alternative free-response receiver operating characteristic analysis. Noninferiority of LDCT compared with SDCT was declared when the lower limit of the 95% CI for the difference in figure of merit (FOM) was greater than -0.10. Results: A total of 296 participants (196 men, 100 women; mean age, 60.5 years +/- 13.3 [SD]) were included. The mean noise level in the liver was significantly lower for LDCT (10.1) compared with SDCT (10.7) (P < .001). Diagnostic performance was assessed in 246 par-ticipants (108 malignant tumors in 90 participants). The reader-averaged FOM was 0.880 for SDCT and 0.875 for LDCT (P = .35). The difference fell within the noninferiority margin (difference, -0.005 [95% CI: -0.024, 0.012]). Conclusion: Compared with SDCT with MBIR, LDCT using 33% of the standard radiation dose had reduced image noise and comparable diagnostic performance in detecting malignant liver tumors. (c) RSNA, 2024
키워드
- 제목
- Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
- 저자
- Lee, Dong Ho; Lee, Jeong Min; Lee, Chang Hee; Afat, Saif; Othman, Ahmed
- 발행일
- 2024-03
- 유형
- Article
- 저널명
- Radiology: Artificial Intelligence
- 권
- 6
- 호
- 2
- 언어
- ENG
- 출판사
- Radiological Society of North America
- 발행국가
- 미국
- ISSN
- P 2638-6100