Intra- and Interobserver Reliability of Size Measurement of Morton Neuromas on Sonography

Citations

WEB OF SCIENCE

8
Citations

SCOPUS

10

초록

Objectives Sonography is often used for analysis of Morton neuromas, but the measurement reliability is unknown. The aim of this study was to determine the intra- and interobserver reliability and precision of sonographic measurement of Morton neuromas. Methods Three observers with different levels of sonography experience (observer A, expert; observer B, intermediate; observer C, beginner) performed repeated measurements of the size of Morton's neuroma in 20 patients. Intraclass correlation coefficient and limit of agreement were used to evaluate reliability and measurement precision. Results The intraclass correlation coefficient for intraobserver reliability was 0.80, 0.71, and 0.43 (limit of agreement, 20%, 18%, and 47%) in observers A, B, and C, respectively. The intraclass correlation coefficient for interobserver reliability was 0.72, 0.38, and 0.38 (limit of agreement, 25%, 36%, and 35%) between observers A/B, A/C, and B/C, respectively. Conclusions The intra- and interobserver reliability values for sonographic measurement of Morton neuroma size were dependent on observer experience. Experienced observers had higher reliability, while observers who were less familiar with sonography showed moderate to low reliability.

키워드

interobserver; intraobserver; Morton neuroma; reliability; ultrasound; CORTICOSTEROID INJECTION; ULTRASOUND; ULTRASONOGRAPHY; INTERRATER; DIAGNOSIS; RATER
제목
Intra- and Interobserver Reliability of Size Measurement of Morton Neuromas on Sonography
저자
Park, Young Hwan; Choi, Wonseok; Choi, Gi Won; Kim, Hak Jun
DOI
10.1002/jum.14928
발행일
2019-09
유형
Article
저널명
Journal of Ultrasound in Medicine
권
38
호
9
페이지
2341 ~ 2345