Sonoanatomical change of phrenic nerve according to posture during ultrasound-guided stellate ganglion block

Citations

SCOPUS

11

초록

Objective To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Methods Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. Results The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Conclusion Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB. © 2016 by Korean Academy of Rehabilitation Medicine.

키워드

Phrenic nerve; Posture; Stellate ganglion; Ultrasound; body posture; clinical article; fascia; female; human; phrenic nerve; skin; stellate ganglion block; sternocleidomastoid muscle; supine position; ultrasound; vertebra
제목
Sonoanatomical change of phrenic nerve according to posture during ultrasound-guided stellate ganglion block
저자
Joeng, Eui Soo; Jeong, Young Cheol ; Park, Bum Jun; Kang, Seok; Yang, Seung Nam; Yoon, Joon Shik
DOI
10.5535/arm.2016.40.2.244
발행일
2016-04
유형
Article
저널명
Annals of Rehabilitation Medicine
권
40
호
2
페이지
244 ~ 251