Impact of Deep Learning-Based Image Conversion on Fully Automated Coronary Artery Calcium Scoring Using Thin-Slice, Sharp-Kernel, Non-Gated, Low-Dose Chest CT Scans: A Multi-Center Study

Citations

WEB OF SCIENCE

6
Citations

SCOPUS

5

초록

Objective: To evaluate the impact of deep learning-based image conversion on the accuracy of automated coronary artery calcium quantification using thin-slice, sharp-kernel, non-gated, low-dose chest computed tomography (LDCT) images collected from multiple institutions. Materials and Methods: A total of 225 pairs of LDCT and calcium scoring CT (CSCT) images scanned at 120 kVp and acquired from the same patient within a 6-month interval were retrospectively collected from four institutions. Image conversion was performed for LDCT images using proprietary software programs to simulate conventional CSCT. This process included 1) deep learning-based kernel conversion of low-dose, high-frequency, sharp kernels to simulate standard-dose, low-frequency kernels, and 2) thickness conversion using the raysum method to convert 1-mm or 1.25-mm thickness images to 3-mm thickness. Automated Agaston scoring was conducted on the LDCT scans before (LDCT-Orgauto) and after the image conversion (LDCT-CONVauto). Manual scoring was performed on the CSCT images (CSCTmanual) and used as a reference standard. The accuracy of automated Agaston scores and risk severity categorization based on the automated scoring on LDCT scans was analyzed compared to the reference standard, using the Bland–Altman analysis, concordance correlation coefficient (CCC), and weighted kappa (κ) statistic. Results: LDCT-CONVauto demonstrated a reduced bias for Agaston score, compared with CSCTmanual, than LDCT-Orgauto did (-3.45 vs. 206.7). LDCT-CONVauto showed a higher CCC than LDCT-Orgauto did (0.881 [95% confidence interval {CI}, 0.750–0.960] vs. 0.269 [95% CI, 0.129–0.430]). In terms of risk category assignment, LDCT-Orgauto exhibited poor agreement with CSCTmanual (weighted κ = 0.115 [95% CI, 0.082–0.154]), whereas LDCT-CONVauto achieved good agreement (weighted κ = 0.792 [95% CI, 0.731–0.847]). Conclusion: Deep learning-based conversion of LDCT images originally obtained with thin slices and a sharp kernel can enhance the accuracy of automated coronary artery calcium score measurement using the images. © 2025 The Korean Society of Radiology.

키워드

Artificial intelligence; Calcium; Coronary vessels; Thorax; Tomography, X-ray computed; ITERATIVE MODEL RECONSTRUCTION; ALL-CAUSE MORTALITY; COMPUTED-TOMOGRAPHY; RISK-FACTORS; CALCIFICATION; PREDICTION; EVENTS; ALGORITHM; DISEASE
제목
Impact of Deep Learning-Based Image Conversion on Fully Automated Coronary Artery Calcium Scoring Using Thin-Slice, Sharp-Kernel, Non-Gated, Low-Dose Chest CT Scans: A Multi-Center Study
저자
Kim, Cherry; Hong, Sehyun; Choi, Hangseok; Yoo, Won-Seok; Kim, Jin Young; Chang, Suyon; Park, Chan Ho; Hong, Su Jin; Yang, Dong Hyun; Yong, Hwan Seok; van Assen, Marly; De Cecco, Carlo N.; Suh, Young Joo
DOI
10.3348/kjr.2025.0177
발행일
2025-08
유형
Article
저널명
Korean Journal of Radiology
권
26
호
6
페이지
759 ~ 770