Metallic Mercury Injection in the Hand Caused by A Broken Mercury Thermometer: A Case Report

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

5

초록

Incorrect usage of or accidents related to metallic mercury can be hazardous. Herein, we present a case of subcutaneous metallic mercury injection in the hand caused by a broken thermometer and surgical tips for this injury. A 43-year-old female patient visited our hospital due to mercurial injection injury at the left hand suffered 4 weeks previously. On gross findings, the mercury deposition was limited to the subcutaneous layer and enveloped by granulation tissue. The blood mercury level, which had been abnormally elevated, fortunately decreased to within normal levels within five months. Nonetheless, this initial elevation indicates the possibility of systemic complications after local absorption of mercury droplets into the general circulation. In conclusion, we recommend prompt and complete excision of mercury material to prevent local and systemic complications, and excising the granulation tissue in its entirety, while retaining the mercury droplets within, is recommended.

키워드

Hand injury; Local and systemic complication; Metallic mercury; Thermometer; mercury; adult; adverse device effect; case report; complication; differential diagnosis; female; finger injury; foreign body; hand; human; mercurialism; procedures; radiography; subcutaneous drug administration; synovectomy; thermometer; three dimensional imaging; x-ray computed tomography; Adult; Diagnosis, Differential; Female; Finger Injuries; Foreign Bodies; Hand; Humans; Imaging, Three-Dimensional; Injections, Subcutaneous; Mercury; Mercury Poisoning; Radiography; Synovectomy; Thermometers; Tomography, X-Ray Computed
제목
Metallic Mercury Injection in the Hand Caused by A Broken Mercury Thermometer: A Case Report
저자
Kim, Dongmin; Park, Jong Woong
DOI
10.1142/S0218810417720376
발행일
2017-12
유형
Article
저널명
The Journal of Hand Surgery (Asian-Pacific Volume)
권
22
호
4
페이지
519 ~ 522