Reference values of fractionated neurography of the ulnar nerve at the wrist in healthy subjects

Citations

WEB OF SCIENCE

10
Citations

SCOPUS

11

초록

Objective: This study is designed to derive a normative database for nerve conduction values of the ulnar nerve in the wrist. Methods: Ulnar nerve study at the wrist (UNSW) was performed in 204 hands of 102 control subjects. The UNSW was composed of motor and sensory tests. Motor UNSW was done with first dorsal interosseous muscle recording. Sensory UNSW was performed antidromically with fifth finger recording. The 3 stimulation points were 2 cm proximal to the pisiform, just lateral to pisiform, and 3 cm distal to the pisiform. Results: Mean latency differences in the proximal and distal segments were 0.4 +/- 0.1 and 0.5 +/- 0.1 ms in motor UNSW and 0.4 +/- 0.1 and 0.5 +/- 0.1 ms in sensory UNSW. The 95th percentile values for motor and sensory UNSW were 0.5 ms in the proximal segment and 0.7 ms in the distal segment. Conclusions: When the 95-percentile value was considered as the normal upper limit, the criteria of abnormality for motor and sensory UNSW were greater than 0.5 ms in the proximal segment and greater than 0.7 ms in the distal segment. Significance: The normative values of UNSW may be useful in screening for ulnar neuropathy at the wrist. (c) 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

키워드

ulnar neuropathy; wrist; nerve conduction study; motor; sensory; Guyon's canal; CARPAL-TUNNEL-SYNDROME; CONDUCTION ABNORMALITIES; INCHING TECHNIQUES; NEUROPATHY; DISTAL; LOCALIZATION; SEGMENT; LESIONS; ENTRAPMENT; STIMULATOR
제목
Reference values of fractionated neurography of the ulnar nerve at the wrist in healthy subjects
저자
Kim, DH; Kang, YK; Hwang, M; Kwon, HK; Lee, HJ; Kim, BG
DOI
10.1016/j.clinph.2005.08.002
발행일
2005-12
유형
Article
저널명
Clinical Neurophysiology
권
116
호
12
페이지
2853 ~ 2857