Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable

Citations

SCOPUS

12

초록

To promote rapid bone healing, an adequate stable fixation implant with a percutaneous reduction instrument should be used for Vancouver type B1 or C fractures. The objective of this study was to describe radiographic and clinical outcomes of patients with periprosthetic fracture (PPF) around a stable femoral stem, treated with a distal femoral locking plate alone or with a cerclage cable. A total of 21 patients with PPF amenable to either a reverse distal femoral locking plate (LCP DF®) alone or with a cerclage cable, with a mean age of 75.7 years, were included. In these patients, ten fractures were treated with a reverse LCP DF® alone and were classified as group I, and 11 additionally received a cerclage cable and were classified as group II. Group II had a significantly longer operation time (P = 0.019) than group I and included one patient with nonunion at the final 24-month follow-up visit after the initial fracture reduction. However, this difference in nonunion rate for the two groups is more likely to inappropriate indications than surgical techniques. When comparing the stability of the fractures in both groups, there was no statistically significant difference, which might be attributed to the stable fixed-angle implant.

키워드

Cerclage cable; Distal femoral locking plate; Minimally invasive plate osteosynthesis; Periprosthetic fracture; Total hip arthroplasty; aged; Article; bone implant; bone plate; bone wire; cerclage cable; clamp; clinical article; clinical outcome; controlled study; distal femoral locking plate; distal femur; female; femoral stem; fracture nonunion; human; male; operation duration; patient coding; periprosthetic fracture; plate fixation; priority journal; prospective study; radiodiagnosis; randomized controlled trial; total knee arthroplasty; treatment indication; bone plate; comparative study; devices; diagnostic imaging; falling; follow up; fracture nonunion; hip prosthesis; hip replacement; osteosynthesis; periprosthetic fracture; very elderly; Accidental Falls; Aged; Aged, 80 and over; Arthroplasty, Replacement, Hip; Bone Plates; Bone Wires; Female; Follow-Up Studies; Fracture Fixation, Internal; Fractures, Ununited; Hip Prosthesis; Humans; Male; Operative Time; Periprosthetic Fractures; Prospective Studies
제목
Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable
저자
Shin, Young-Soo; Han, Seung Beom
DOI
10.1007/s00590-017-1900-5
발행일
2017-07
유형
Article
저널명
European Journal of Orthopaedic Surgery and Traumatology
권
27
호
5
페이지
623 ~ 630