Radial head prosthesis micromotion characteristics: Partial versus fully grit-blasted stems

  • Chanlalit C.; 
  • Fitzsimmons J.S.; 
  • Moon J.-G.; 
  • Berglund L.J.; 
  • An K.-N.; 
  • 외 1명
Citations

SCOPUS

17

초록

Background: Compared to fully textured prosthetic stems, partial texturing lessens bone loss due to stress shielding and makes removal easier. However, initial press-fit stability is necessary for bone ingrowth. Hypothesis: There is no significant difference in the initial stability of radial head prostheses that are partially grit-blasted compared to those that are fully grit-blasted. Materials and methods: Cadaveric radii were implanted with partial or fully grit-blasted radial head prostheses. Micromotion of the stem at the isthmus of the canal and stem tip were measured under circumstances simulating eccentric loads. Results: Micromotion was not significantly different in the fully grit-blasted stems (isthmus, 11 ± 1 μm; tip, 21 ± 2 μm) and partially grit-blasted stems (isthmus, 13 ± 2 μm; tip, 25 ± 2 μm) (P = 0.4). The direction of loading had no effect on micromotion characteristics in either the fully or partially grit-blasted stems (P = .07). Discussion: Micromotion is comparable in partially and fully grit-blasted radial head prosthetic stems. For both stem surfaces, micromotion was well within the range that is conducive for bone ingrowth. A partially textured stem might have less bone loss due to stress shielding, making it easier to remove without destroying bone. Conclusion: The initial stability of a radial head stem that is partially grit-blasted only at the proximal end is comparable to that of a radial head stem that is grit-blasted along its entire length. © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.

키워드

Basic Science Study; Grit-blasted stem; Initial stability, stem surface; Radial head prosthesis; Stress shielding; arm prosthesis; article; bone growth; cadaver; human; intermethod comparison; priority journal; radial head prosthesis; radiography; range of motion; Aged; Aged, 80 and over; Arthroplasty, Replacement, Elbow; Elbow Prosthesis; Female; Humans; Male; Movement; Radius; Stress, Mechanical; Surface Properties
제목
Radial head prosthesis micromotion characteristics: Partial versus fully grit-blasted stems
저자
Chanlalit C.; Fitzsimmons J.S.; Moon J.-G.; Berglund L.J.; An K.-N.; O'Driscoll S.W.
DOI
10.1016/j.jse.2010.05.030
발행일
2011
유형
Article
저널명
Journal of Shoulder and Elbow Surgery
권
20
호
1
페이지
27 ~ 32