A nanopatterned interdigitated electrode array (nanoIEA)-based impedance assay is developed for quantitative real-time measurement of aligned endothelial cell (EC) barrier functions in vitro. A bioinspired poly(3,4-dihydroxy-L-phenylalanine) (poly (l-DOPA)) coating is applied to improve the human brain EC adhesion onto the Nafion nanopatterned surfaces. It is found that a poly (l-DOPA)-coated Nafion grooved nanopattern makes the human brain ECs orient along the nanopattern direction. Aligned human brain ECs on Nafion nanopatterns exhibit increased expression of genes encoding tight and adherens junction proteins. Aligned human brain ECs also have enhanced impedance and resistance versus unaligned ones. Treatment with a glycogen synthase kinase-3 inhibitor (GSK3i) further increases impedance and resistance, suggesting synergistic effects occur on the cell-cell tightness of in vitro human brain ECs via a combination of anisotropic matrix nanotopography and GSK3i treatment. It is found that this enhanced cell-cell tightness of the combined approach is accompanied by increased expression of claudin protein. These data demonstrate that the proposed nanoIEA assay integrated with poly (l-DOPA)-coated Nafion nanopatterns and interdigitated electrode arrays can make not only biomimetic aligned ECs, but also enable real-time measurement of the enhanced barrier functions of aligned ECs via tighter cell-cell junctions. A nanopatterned interdigitated electrode array (nanoIEA)-based impedance assay with a bioinspired poly (l-DOPA) coating is developed for quantitative real-time measurement of aligned endothelial cell barrier functions. GSK3 inhibition further increases impedance and resistance, suggesting synergistic effects occur on the cell-cell tightness of aligned endothelial cells via a combination of matrix anisotropy and GSK3i treatment.image

키워드

endothelial barrier function; impedance assays; interdigitated electrodes; nanopatterned Nafion; poly (L-DOPA); BLOOD-BRAIN-BARRIER; FABRICATION; PROTEIN; FLOW
제목
NanoIEA: A Nanopatterned Interdigitated Electrode Array-Based Impedance Assay for Real-Time Measurement of Aligned Endothelial Cell Barrier Functions
저자
Choi, Jong Seob; Doo, Hyun Myung; Kim, Byunggik; Lee, Su Han; Sung, Sang-keun; Go, Gwangjun; Suarez, Allister; Kim, Yeseul; Weon, Byung Mook; Choi, Byung-Ok; Kim, Hyung Jin; Kim, Deok-Ho
DOI
10.1002/adhm.202301124
발행일
2024-01
유형
Article
저널명
Advanced Healthcare Materials
권
13
호
2