Simple overlay device for determining radial head and neck height

  • Moon J.-G.; 
  • Southgate R.D.; 
  • Fitzsimmons J.S.; 
  • O'Driscoll S.W.
Citations

SCOPUS

6

초록

Background: The purpose of this study was to test the hypothesis that a simple overlay device can be used on radiographs to measure radial head and neck height. Materials and methods: Thirty anteroposterior elbow radiographs from 30 patients with a clinical diagnosis of lateral epicondylitis were examined to measure radial head and neck height. Three methods using different points along the bicipital tuberosity as a landmark were used. Method 1 used the proximal end of the bicipital tuberosity, method 2 used the most prominent point of the bicipital tuberosity, and method 3 used a simple overlay device (SOD) template that was aligned with anatomic reference points. All measurements were performed three times by three observers to determine interobserver and intraobserver reliability. Results: Intraclass correlation coefficients revealed higher interobserver and intraobserver correlations for the SOD template method than for the other two methods. The 95% limits of agreement between observers were markedly better (-1.8 mm to +1.0 mm) for the SOD template method than for the proximal point method (-3.8 mm to +3.4 mm) or the prominent point method (-5.9 mm to +4.9 mm). Conclusions: We found that the SOD template method was reliable for assessing radial head and neck height. It had less variability than other methods, its 95% limit of agreement being less than 2 mm. This method could be helpful for assessing whether or not the insertion of a radial head prosthesis has resulted in over-lengthening of the radius. © 2010 US government.

키워드

Anatomy; Bicipital tuberosity; Biomechanics; Overstuffing; Prosthesis; Radial head; Radiographs; Template; adult; arm prosthesis; article; bicipital tuberosity; clinical article; elbow radiography; female; human; intermethod comparison; interrater reliability; intrarater reliability; male; orthopedic equipment; priority journal; radius; radius head; radius head prosthesis; radius neck; simple overlay device; tennis elbow; Adult; Equipment Design; Equipment Failure Analysis; Female; Humans; Male; Middle Aged; Radiography; Radius; Reproducibility of Results; Sensitivity and Specificity; Tennis Elbow; X-Ray Film
제목
Simple overlay device for determining radial head and neck height
저자
Moon J.-G.; Southgate R.D.; Fitzsimmons J.S.; O'Driscoll S.W.
DOI
10.1007/s00256-010-0893-5
발행일
2010
유형
Article
저널명
Skeletal Radiology
권
39
호
9
페이지
915 ~ 920