상세 보기
초록
The rapid immunocapture assays, OptiMal and ICT, were evaluated from 87 individuals for the diagnosis of malaria infections directly from whole blood. A total of 87 individuals was examined for malaria parasites by microscopic examination of Giemsa-stained blood smears, and 65 cases were positive for Plasmodium vivax by microscopy. Correspondingly, the OptiMal test identified malaria infection in 45 cases (69.2%) of microscopy positive cases. Of these, two cases were misinterpreted as Plasmodium falciparum, whereas ICT detected P. vivax infection in 29 (44.6%) patients. We would like to propose that rapid immune capture assays are an easy method that can serve as a useful tool in addition to microscopy for the diagnosis of malaria, but sensitivity is not yet satisfactory for diagnosis of P. vivax in Korea.
키워드
- 제목
- Evaluation of rapid immunocapture assays for diagnosis of Plasmodium vivax in Korea
- 저자
- Cho, D; Kim, KH; Park, SC; Kim, YK; Lee, KN; Lim, CS
- 발행일
- 2001-06
- 유형
- Article
- 권
- 87
- 호
- 6
- 페이지
- 445 ~ 448
- 언어
- ENG
- 출판사
- Springer Verlag
- 발행국가
- 미국
- 분량
- 4 페이지
- ISSN
- E 1432-1955
P 0932-0113