상세 보기
Comparison of linac-based fractionated stereotactic radiotherapy and tomotherapy treatment plans for intra-cranial tumors
- Shim, Jang Bo;
- Lee, Suk;
- Cho, Sam Ju;
- Lee, Sang Hoon;
- Kim, Juree;
- ... Yoon, Won Seob;
- ... Chul Yong, Kim;
- 외 7명
WEB OF SCIENCE
0SCOPUS
0초록
This study compares and analyzes stereotactic radiotherapy using tomotherapy and linac-based fractionated stereotactic radiotherapy in the treatment of intra-cranial tumors, according to some cases. In this study, linac-based fractionated stereotactic radiotherapy and tomotherapy treatment were administered to five patients diagnosed with intra-cranial cancer in which the dose of 18-20 Gy was applied on 3 T) separate occasions. The tumor dosing was decided by evaluating the inhomogeneous index (II) and conformity index (CI). Also, the radiation-sensitive tissue was evaluated using low dose factors V-1, V-2, V-3, V-4, V-5, and V-10, as well as the non-irradiation ratio volume (NIV). The values of the II for each prescription dose in the linac-based non-coplanar radiotherapy plan and tomotherapy treatment plan were (0.125 +/- 0.113) and (0.090 +/- 0.180), respectively, and the values of the CI were (0.899 +/- 0.149) and (0.917 +/- 0.114), respectively. The low dose areas, V-1, V-2, V-3, V-4, V-5, and V-10, in radiation-sensitive tissues in the linac-based non-coplanar radiotherapy plan fell into the ranges 0.3%-95.6%, 0.1%-87.6%, 0.1%-78.8%, 38.8%-69.9%, 26.6%-65.2%, and 4.2%-39.7%, respectively, and the tomotherapy treatment plan had ranges of 13.6%-100%, 3.5%-100%, 0.4%-94.9%, 0.2%-82.2%, 0.1%-78.5%, and 0.3%-46.3%, respectively. Regarding the NIV for each organ, it is possible to obtain similar values except for the irradiation area of the brain stem. The percentages of NIV10%, NIV20%, and NIV30% for the brain stem in each patient were 15%-99.8%, 33.4%-100%, and 39.8%-100%, respectively, in the fractionated stereotactic treatment plan and 44.2%-96.5%, 77.7%-99.8%, and 87.8%-100%, respectively, in the tomotherapy treatment plan. In order to achieve higher-quality treatment of intra-cranial tumors, treatment plans should be tailored according to the isodose target volume, inhomogeneous index, conformity index, position of the tumor upon fractionated stereotactic radiosurgery, and radiation dosage for radiation-sensitive tissues.
키워드
- 제목
- Comparison of linac-based fractionated stereotactic radiotherapy and tomotherapy treatment plans for intra-cranial tumors
- 저자
- Shim, Jang Bo; Lee, Suk; Cho, Sam Ju; Lee, Sang Hoon; Kim, Juree; Cho, Kwang Hwan; Min, Chul Kee; Huh, Hyun Do; Lee, Rena; Yang, Dae Sik; Park, Young Je; Yoon, Won Seob; Chul Yong, Kim; Kwon, Soo Il
- 발행일
- 2010-11
- 유형
- Article
- 권
- 34
- 호
- 11
- 페이지
- 1768 ~ 1774
- 언어
- ENG
- 출판사
- Institute of Physics Publishing
- 발행국가
- 영국
- 분량
- 7 페이지
- ISSN
- E 2058-6132
P 1674-1137