상세 보기
Clinical impact of angiographically insignificant suboptimal poststent findings detected by optical coherence tomography after drug-eluting stent implantation
- Cho, Jae Young;
- Kook, Hyung don;
- Yu, Cheol Woong
WEB OF SCIENCE
0SCOPUS
0초록
Background Although optical coherence tomography (OCT)-detected suboptimal findings (SF-OCT) such as malapposition, edge dissection, tissue protrusion, thrombus and small minimal stent area (MSA) are frequently observed after the implantation of drug-eluting stents (DES), their clinical implications are controversial. Hypothesis Clinical outcomes may differ between patients with SF-OCTs and without SF-OCTs after DES implantation. Methods A total of 576 patients undergoing OCT analysis after DES implantation were divided into SF-OCT group (n = 379, 379 lesions) and No SF-OCT group (n = 197, 197 lesions). The study population had no significant abnormal finding in final angiography. Quantification was performed for each SF-OCT. The incidences of major adverse cardiovascular events (MACE: all-cause death, non-fatal myocardial infarction, target vessel revascularization, and stent thrombosis) were compared between the two groups. A median follow-up duration was 21.5 months. Results Among 379 patients with SF-OCT, 32.4% had multiple SF-OCTs. Malapposition (32.1%, IQR of maximal depth 315–580 μm) was the most frequent, followed by small MSA (31.6%), edge dissection (12.5%, IQR of maximal flap of opening 0.27–0.52 mm), thrombus (7.6%, IQR of diameter 1.31–1.97mm) and tissue protrusion (6.8%, IQR of diameter 1.05–1.67 mm). The SF-OCT group showed smaller stent diameter and longer stent length, and lower in-stent lumen expansion rate. The incidence of MACE did not differ between the two groups (3.0% for No SF-OCT vs. 5.0% for SF-OCT; HR 1.601; 95% CI 0.639 to 4.011; P = 0.310). Conclusions The presence of angiographically insignificant SF-OCTs were not associated with clinical outcomes in this study.
키워드
- 제목
- Clinical impact of angiographically insignificant suboptimal poststent findings detected by optical coherence tomography after drug-eluting stent implantation
- 저자
- Cho, Jae Young; Kook, Hyung don; Yu, Cheol Woong
- 발행일
- 2020-10
- 유형
- Article
- 저널명
- PLoS One
- 권
- 15
- 호
- 10
- 언어
- ENG
- 출판사
- Public Library of Science
- 발행국가
- 미국
- ISSN
- P 1932-6203