Prevention of arachnoiditis and postoperative tethering of the spinal cord with Gore-Tex surgical membrane: An experimental study with rats

Citations

SCOPUS

51

초록

OBJECTIVE: Arachnoidal adhesions and inflammation were evaluated in 72 rats after spinal dural repair with one of three materials, i.e., Gore-Tex surgical membrane, collagen-coated Vicryl mesh, or lyophilized spinal dural allograft. METHODS: Laminectomy at L1 was performed, and then a 3- x 4-mm segment of spinal dura mater and arachnoid membrane was excised. After implantation of the dural substitute, the animals were divided into normal and injured groups. In the injured group, a spinal cord injury was produced at the midpoint of the duraplasty site by the clip compression technique, with 25-g force for 1 minute. Neurological performance was assessed by the inclined plane technique, and groups of rats were killed at 8 to 24 weeks after surgery. The spinal column was removed en bloc and processed for histological examination. RESULTS: There were no differences in neurological function among the three dural substitutes in either injured or noninjured rats. However, there were major differences among the groups in the incidence and severity of arachnoid adhesions and tethering. The neural tissue was bound to a thick neomembrane surrounding the lyophilized dural allograft and the collagen-coated Vicryl mesh. In contrast, the Gore-Tex surgical membrane induced only a thin membranous adhesion, which was loose and flexible. The inflammatory and foreign body response was most pronounced in rats treated with collagen-coated Vicryl mesh, at 8 and 24 weeks. CONCLUSION: In the present study, Gore-Tex surgical membrane was a very good material for the surgical repair of spinal dural defects. Additional experimental studies are required to compare Gore-Tex membrane with autologous tissues.

키워드

Collagen-coated Vicryl mesh; Dural repair; Dural substitute; Gore-Tex surgical membrane; Lyophilized dura; Spinal cord; collagen; politef; polyglactin; adhesion; allograft; animal experiment; animal model; animal tissue; arachnoiditis; article; brain arachnoid; controlled study; dura mater; female; foreign body reaction; freeze drying; inflammation; laminectomy; membrane; nonhuman; politef implant; priority journal; rat; spinal cord injury; tethered cord syndrome; Animals; Arachnoiditis; Collagen; Dura Mater; Female; Membranes, Artificial; Nervous System; Polyglactin 910; Polytetrafluoroethylene; Postoperative Complications; Prostheses and Implants; Rats; Rats, Wistar; Spina Bifida Occulta; Spinal Cord; Surface Properties; Surgical Mesh; Wound Healing
제목
Prevention of arachnoiditis and postoperative tethering of the spinal cord with Gore-Tex surgical membrane: An experimental study with rats
저자
Park Y.-K.; Tator C.H.
DOI
10.1097/00006123-199804000-00076
발행일
1998
유형
Article
저널명
Neurosurgery
권
42
호
4
페이지
813 ~ 824