Evaluation of Implant Stability According to Implant Placement Site and Duration in Elderly Patients: A Prospective Multi-Center Cohort Study

  • Shim, Ji-Suk; 
  • Kim, Moon-Young; 
  • An, Se-Jun; 
  • Kang, Eun-Sung; 
  • Choi, Yu-Sung
Citations

WEB OF SCIENCE

8
Citations

SCOPUS

10

초록

The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.0/4.5/5.0 mm and length: 8.5/10.0/11.5 mm) in 60 patients aged & GE; 65 years. The implant placement sites were divided into six evenly distributed sections (n = 10), i.e., maxillary right-posterior, A; maxillary anterior, B; maxillary left-posterior, C; mandibular right-posterior, D; mandibular anterior, E; mandibular left-posterior, F. Participants visited the hospital six times: implant surgery, 1V; stitch removal, 2V; 1-month follow-up, 3V; 2-month follow-up, 4V; before final restoration delivery, 5V; and after final restoration delivery, 6V. The implant stability was evaluated with the Osstell Mentor (ISQ), Periotest M (PTV), and Anycheck (IST). The mean values of ISQ, PTV, and IST were analyzed (& alpha; = 0.05). ISQ, PTV, and IST results of 4V and 5V were significantly higher than those of 1V (p < 0.05). The lowest ISQ results occurred in the E location at 4V and 5V (p < 0.05). In all mandibular locations, IST results of 6V were significantly higher than those of 1V, 2V, 3V, and 4V (p < 0.05). ISQ results were negatively correlated with PTV and positively correlated with IST, and PTV was negatively correlated with IST. By considering various factors affecting the stability of the implant, it is necessary to determine the appropriate implant load application time. This could help increase the implant success rate in elderly patients. And as a diagnostic device for implant stability and the evaluation of osseointegration in elderly patients, Anycheck was also able to prove its relative reliability compared to Osstell ISQ Mentor and Periotest M.

키워드

implant stability; implant stability quotient; Periotest value; implant stability test; prospective study; elderly patient; AGE-RELATED-CHANGES; RESONANCE FREQUENCY; DAMPING CAPACITY; DEVICE; PERIOTEST; RELIABILITY; PARAMETERS; SURVIVAL
제목
Evaluation of Implant Stability According to Implant Placement Site and Duration in Elderly Patients: A Prospective Multi-Center Cohort Study
저자
Shim, Ji-Suk; Kim, Moon-Young; An, Se-Jun; Kang, Eun-Sung; Choi, Yu-Sung
DOI
10.3390/jcm12155087
발행일
2023-08
유형
Article
저널명
Journal of Clinical Medicine
권
12
호
15