Comparison of neoatherosclerosis and clinical outcomes between bioabsorbable versus durable polymer drug-eluting stent: Verification by optical coherence tomography analysis

  • Cho, Jae Young; 
  • Kook, Hyungdon; 
  • Anvarov, Javoxir; 
  • Makhkamov, Najmiddin; 
  • Cho, Sang -A; 
  • ... Yu, Cheol Woong
Citations

WEB OF SCIENCE

4

초록

Background Neoatherosclerosis after drug-eluting stent (DES) implantation is known to be related with increased risk of late restenosis and stent thrombosis. Neoatherosclerosis and relevant clinical outcomes between bioabsorbable polymer DES (BP-DES) and second-generation durable polymer DES (DP-DES) were evaluated by optical coherence tomography (OCT) analysis. Methods A total of 311 patients (319 lesions) undergoing OCT analysis after DES implantation were enrolled and divided into two groups according to stent type (BP-DES [150 patients, 153 lesions] and DP-DES [161 patients, 166 lesions]). Follow-up OCT analysis was performed at least 9 months after index stent implantation. Neoatherosclerosis was defined as presence of thin-cap fibroatheroma, calcified plaque, and lipid plaque. Primary endpoint was the incidence of neoatherosclerosis, and the secondary endpoints were the occurrence of major adverse cardiac events (MACE), defined as a composite of death, myocardial infarction, target lesion revascularization, or stent thrombosis and to find independent predictors of neoatherosclerosis. Results The incidence of neoatherosclerosis was lower in the BP-DES group than the DP-DES group (5.2% vs. 14.5%, p = 0.008), which was driven by lipid plaque. However, the incidence of MACE did not show statistical difference between the two groups in median 4-year follow-up (3.3% vs. 7.8%, hazard ratio 1.964, 95% confidence interval 0.688–5.611, p = 0.207). Less use of angiotensin converting enzyme inhibitors/angiotensin II receptor blockade and higher degree of neointimal hyperplasia remained independent predictors of neoatherosclerosis on Cox regression analysis. Conclusions Patients undergoing BP-DES implantation had lower incidence of neoatherosclerosis than DP-DES, which did not reach statistically better clinical outcomes.

키워드

neointima; coronary restenosis; drug-eluting stents; tomography; optical coherence; BARE-METAL; BIODEGRADABLE POLYMER; CORONARY STENT; IMPLANTATION; THROMBOSIS; METAANALYSIS; INDUCTION; TRIALS
제목
Comparison of neoatherosclerosis and clinical outcomes between bioabsorbable versus durable polymer drug-eluting stent: Verification by optical coherence tomography analysis
저자
Cho, Jae Young; Kook, Hyungdon; Anvarov, Javoxir; Makhkamov, Najmiddin; Cho, Sang -A; Yu, Cheol Woong
DOI
10.5603/CJ.a2022.0025
발행일
2023-12
유형
Article
저널명
Cardiology Journal
권
30
호
6
페이지
911 ~ 920