Detailed Information

Cited 45 time in webofscience Cited 45 time in scopus
Metadata Downloads

Evaluation of a novel real-time RT-PCR using TOCE technology compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Chi Hyun-
dc.contributor.authorChulten, Bayarjavkhlan-
dc.contributor.authorLee, Chang Kyu-
dc.contributor.authorNam, Myung Hyun-
dc.contributor.authorYoon, Soo Young-
dc.contributor.authorLim, Chae Seung-
dc.contributor.authorCho, Yunjung-
dc.contributor.authorKim, Young Kee-
dc.date.available2020-11-02T20:45:46Z-
dc.date.issued2013-08-
dc.identifier.issn1386-6532-
dc.identifier.issn1873-5967-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/10500-
dc.description.abstractBackground: Various kinds of commercial molecular systems have been developed for fast and more accurate detection of respiratory viruses. Anyplex (TM) II RV16 [RV16] was designed for simultaneous detection of 16 respiratory viruses using multiplex PCR coupled with TOCE (TM) technology. Objectives: To compare the performance of RV16 with those of culture and Seeplex (R) RV15 ACE [RV15] by determining their sensitivity and specificity. Study design: Seven hundred and thirty respiratory samples were tested by modified shell vial culture method, RV16, and RV15. For molecular tests, automated nucleic acid extraction and liquid handling system using MICROLAB Nimbus IVD (Hamilton, USA) was adopted to maximize the workflow and accuracy. Performance of each assay was determined against a composite reference standard. Results: Two hundred and one samples (28%) out of 730 samples were positive by culture, while additional 281 (39%) were positive by RV16 or RV15. Sensitivities of RV16, RV15, and culture for virus tested were as follows: 100/93/63% for influenza A, 90/80/69% for influenza B, 98/94/63% for RSV, 98/52/23% for adenovirus, and 100/75/46% for PIV. For viruses not covered by culture, sensitivities of RV16 and RV15 were as follows: 99/81% for rhinovirus, 92/100% for coronavirus OC43, 100/56% for coronavirus 229E/NL63, 92/88% for metapneumovirus, 100/62% for bocavirus, and 91/91% for enterovirus. Overall, the specificities of culture, RV16, and RV15 (Seegene) were 100/99.9/99.9%. Conclusions: RV16 assay was superior to culture method and RV15 and will be a promising tool for patient management and public health epidemiology. (C) 2013 Elsevier B.V. All rights reserved.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER-
dc.titleEvaluation of a novel real-time RT-PCR using TOCE technology compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.jcv.2013.04.014-
dc.identifier.scopusid2-s2.0-84879262302-
dc.identifier.wosid000320593800009-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL VIROLOGY, v.57, no.4, pp 338 - 342-
dc.citation.titleJOURNAL OF CLINICAL VIROLOGY-
dc.citation.volume57-
dc.citation.number4-
dc.citation.startPage338-
dc.citation.endPage342-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaVirology-
dc.relation.journalWebOfScienceCategoryVirology-
dc.subject.keywordPlusIDENTIFICATION-
dc.subject.keywordPlusASSAYS-
dc.subject.keywordPlusCORONAVIRUS-
dc.subject.keywordPlusOUTBREAKS-
dc.subject.keywordPlusCHILDREN-
dc.subject.keywordPlusPANEL-
dc.subject.keywordAuthorRespiratory virus-
dc.subject.keywordAuthorViral isolation-
dc.subject.keywordAuthorMultiplex RT PCR-
dc.subject.keywordAuthorReal-time-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Laboratory Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Yunjung photo

Cho, Yunjung
Anam Hospital (Department of Laboratory Medicine, Anam Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE