Detailed Information

Cited 9 time in webofscience Cited 20 time in scopus
Metadata Downloads

Detailed comparison of robotic and endoscopic transaxillary thyroidectomy

Full metadata record
DC Field Value Language
dc.contributor.authorChang, Young Woo-
dc.contributor.authorLee, Hye Yoon-
dc.contributor.authorJi, Woong Bae-
dc.contributor.authorKim, Hoon Yub-
dc.contributor.authorKim, Woo Young-
dc.contributor.authorLee, Jae Bok-
dc.contributor.authorSon, Gil Soo-
dc.date.available2020-11-02T06:25:55Z-
dc.date.issued2020-01-
dc.identifier.issn1015-9584-
dc.identifier.issn0219-3108-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/1178-
dc.description.abstractBackground: Robotic thyroidectomy is increasingly used for patients with papillary thyroid carcinoma (PTC). We compared the differences between robotic and endoscopic transaxillary thyroidectomy with regard to surgical procedures. Methods: This retrospective study enrolled 40 patients with PTC who underwent robotic hemithyroidectomy (robot group) using the Da Vinci S system and 37 patients (endoscopic group) who underwent endoscopic hemithyroidectomy. Video files of surgery for all patients were analyzed to compare the operation procedures: (flap creation, docking [only for robot group], dissection of the superior pole, dissection of the inferior pole, identification of parathyroid glands [PTGs] and the recurrent laryngeal nerve [RLN], dissection of the thyroid along the trachea, bleeding control, application of a drain, and wound closure). The duration of each procedure and the clinicopathological characteristics were analyzed. Results: Procedure time for patients in the robot group was shorter for inferior pole dissection and for identification of the PTGs and RLN (37.5 min vs. 50.5 min, p = 0.008). Mean total operative times for the two groups were comparable (153.0 min vs. 150.2 min, p = 0.732); however, excluding the docking procedure, operation time was shorter for the robot group (133.3 min vs. 150.2 min, p = 0.038). The number of sacrificed PTGs was also significantly smaller in the robot group (0.35 +/- 0.53 vs. 0.65 +/- 0.68, p = 0.036). Conclusion: Compared to endoscopic thyroidectomy, robotic transaxillary thyroidectomy involved a shorter time for inferior pole dissection and PTGs and RLN identification; moreover, more PTGs were spared using this procedure. (C) 2019 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SINGAPORE PTE LTD-
dc.titleDetailed comparison of robotic and endoscopic transaxillary thyroidectomy-
dc.typeArticle-
dc.publisher.location싱가폴-
dc.identifier.doi10.1016/j.asjsur.2019.02.012-
dc.identifier.scopusid2-s2.0-85062921234-
dc.identifier.wosid000509483400031-
dc.identifier.bibliographicCitationAsian Journal of Surgery, v.43, no.1, pp 234 - 239-
dc.citation.titleAsian Journal of Surgery-
dc.citation.volume43-
dc.citation.number1-
dc.citation.startPage234-
dc.citation.endPage239-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordAuthorEndoscopic thyroidectomy-
dc.subject.keywordAuthorPapillary thyroid carcinoma-
dc.subject.keywordAuthorRobotic thyroidectomy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Anesthesiology and Pain Medicine > 1. Journal Articles
2. Clinical Science > Department of Colon and Rectal Surgery > 1. Journal Articles
2. Clinical Science > Department of Breast and Endocrine Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Hye Yoon photo

Lee, Hye Yoon
Ansan Hospital (Department of Breast and Endocrine Surgery, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE