Feasibility of obtaining quantitative 3-dimensional information using conventional endoscope: A pilot study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jin Hyun J. | - |
dc.contributor.author | Jai Chun H. | - |
dc.contributor.author | Keum B. | - |
dc.contributor.author | Seok Seo Y. | - |
dc.contributor.author | Sik Kim Y. | - |
dc.contributor.author | Tae Jeen Y. | - |
dc.contributor.author | Sik Lee H. | - |
dc.contributor.author | Ho Um S. | - |
dc.contributor.author | Duck Kim C. | - |
dc.contributor.author | Sang Ryu H. | - |
dc.contributor.author | Lim J.-W. | - |
dc.contributor.author | Woo D.-G. | - |
dc.contributor.author | Kim Y.-J. | - |
dc.contributor.author | Lim M.-T. | - |
dc.date.available | 2020-11-03T00:49:35Z | - |
dc.date.issued | 2012-08 | - |
dc.identifier.issn | 2234-2400 | - |
dc.identifier.issn | 2234-2443 | - |
dc.identifier.uri | https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/12718 | - |
dc.description.abstract | Background/Aims: Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods: Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results: The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions: It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object. © 2012 Korean Society of Gastrointestinal Endoscopy. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | Feasibility of obtaining quantitative 3-dimensional information using conventional endoscope: A pilot study | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.5946/ce.2012.45.3.182 | - |
dc.identifier.scopusid | 2-s2.0-84878720602 | - |
dc.identifier.bibliographicCitation | Clinical Endoscopy, v.45, no.3, pp 182 - 188 | - |
dc.citation.title | Clinical Endoscopy | - |
dc.citation.volume | 45 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 182 | - |
dc.citation.endPage | 188 | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001696731 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | 3-dimensional imaging | - |
dc.subject.keywordAuthor | Distortion | - |
dc.subject.keywordAuthor | Endoscopes | - |
dc.subject.keywordAuthor | Epipolar geometry | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
73, Goryeodae-ro, Seongbuk-gu, Seoul, Republic of Korea (02841)82-2-2286-1265
COPYRIGHT 2020 KOREA UNIVERSITY MEDICAL LIBRARY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.