A novel cleansing score system for capsule endoscopy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sung Chul | - |
dc.contributor.author | Keum, Bora | - |
dc.contributor.author | Hyun, Jong Jin | - |
dc.contributor.author | Seo, Yeon Seok | - |
dc.contributor.author | Kim, Yong Sik | - |
dc.contributor.author | Jeen, Yoon Tae | - |
dc.contributor.author | Chun, Hoon Jai | - |
dc.contributor.author | Um, Soon Ho | - |
dc.contributor.author | Kim, Chang Duck | - |
dc.contributor.author | Ryu, Ho Sang | - |
dc.date.available | 2020-11-03T06:50:07Z | - |
dc.date.issued | 2010-02 | - |
dc.identifier.issn | 1007-9327 | - |
dc.identifier.issn | 2219-2840 | - |
dc.identifier.uri | https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/15148 | - |
dc.description.abstract | AIM: To suggest a new cleansing score system for small bowel preparation and to evaluate its clinical efficacy. METHODS: Twenty capsule endoscopy cases were reviewed and small bowel preparation was assessed with the new scoring system. For the assessment, two visual parameters were used: proportion of visualized mucosa and degree of obscuration. Representative frames from small bowel images were serially selected and scored at 5-min intervals. Intraclass correlation coefficient (ICC) was obtained to assess the reliability of the new scoring system. For efficacy evaluation and validation, scores of our new scoring system were compared with another previously reported cleansing grading system. RESULTS: Concordance with the previous system, inter-observer agreement, and intra-patient agreement were excellent with ICC values of 0.82, 0.80, and 0.76, respectively. The intra-observer agreements at four-week intervals were also excellent. The cutoff value of adequate image quality was found to be 2.25. CONCLUSION: Our new scoring system is simple, efficient, and can be considered to be applicable in clinical practice and research. (C) 2010 Baishideng. All rights reserved. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | BAISHIDENG PUBLISHING GROUP INC | - |
dc.title | A novel cleansing score system for capsule endoscopy | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.3748/wjg.v16.i7.875 | - |
dc.identifier.scopusid | 2-s2.0-77449140215 | - |
dc.identifier.wosid | 000274846400011 | - |
dc.identifier.bibliographicCitation | WORLD JOURNAL OF GASTROENTEROLOGY, v.16, no.7, pp 875 - 880 | - |
dc.citation.title | WORLD JOURNAL OF GASTROENTEROLOGY | - |
dc.citation.volume | 16 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 875 | - |
dc.citation.endPage | 880 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.subject.keywordPlus | SMALL-BOWEL PREPARATION | - |
dc.subject.keywordPlus | PUSH ENTEROSCOPY | - |
dc.subject.keywordPlus | CONTROLLED-TRIAL | - |
dc.subject.keywordPlus | VISUALIZATION | - |
dc.subject.keywordPlus | VALIDATION | - |
dc.subject.keywordPlus | QUALITY | - |
dc.subject.keywordAuthor | Capsule endoscopy | - |
dc.subject.keywordAuthor | Cleansing score system | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
73, Goryeodae-ro, Seongbuk-gu, Seoul, Republic of Korea (02841)82-2-2286-1265
COPYRIGHT 2020 KOREA UNIVERSITY MEDICAL LIBRARY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.