Detailed Information

Cited 14 time in webofscience Cited 15 time in scopus
Metadata Downloads

Low-dose multidetector dynamic CT in the breast - Preliminary study

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, BK-
dc.contributor.authorPisano, ED-
dc.contributor.authorCho, KR-
dc.contributor.authorCho, PK-
dc.contributor.authorLee, JY-
dc.contributor.authorKim, SJ-
dc.date.available2020-11-03T15:49:16Z-
dc.date.issued2005-05-
dc.identifier.issn0899-7071-
dc.identifier.issn1873-4499-
dc.identifier.urihttps://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/19732-
dc.description.abstractThis study investigated the feasibility of using low-dose multidetector dynamic computed tomography (CT) scan for imaging breast. We measured the radiation dose using a phantom at low- and standard-dose CT. To compare the image quality at low- and standard-dose CT, we evaluated normal breasts in 57 cases. In 44 cases with breast cancer, we assessed the staging and time-enhancement curves of breast cancer. In conclusion, the low-dose multidetector dynamic CT scan is feasible for the evaluation of the breast, with reduced radiation dose and with similar image quality when compared with standard-dose CT scan. In breast cancers, low-dose dynamic CT could be used for the staging of breast cancer before surgery. (c) 2005 Elsevier Inc. All rights reserved.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE INC-
dc.titleLow-dose multidetector dynamic CT in the breast - Preliminary study-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.clinimag.2004.04.029-
dc.identifier.scopusid2-s2.0-18044370068-
dc.identifier.wosid000229284700003-
dc.identifier.bibliographicCitationCLINICAL IMAGING, v.29, no.3, pp 172 - 178-
dc.citation.titleCLINICAL IMAGING-
dc.citation.volume29-
dc.citation.number3-
dc.citation.startPage172-
dc.citation.endPage178-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusEARLY LUNG-CANCER-
dc.subject.keywordPlusSPIRAL CT-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusHELICAL CT-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordAuthorbreast-
dc.subject.keywordAuthorbreast neoplasms-
dc.subject.keywordAuthorbreast neoplasms-
dc.subject.keywordAuthorCT-
Files in This Item
There are no files associated with this item.
Appears in
Collections
2. Clinical Science > Department of Medical Oncology and Hematology > 1. Journal Articles
1. Basic Science > Department of Biostatistics > 1. Journal Articles
2. Clinical Science > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Bo Kyoung photo

Seo, Bo Kyoung
Ansan Hospital (Department of Radiology, Ansan Hospital)
Read more

Altmetrics

Total Views & Downloads

BROWSE