Development of PDRESS (patient specific dose real evaluation systems) using a TENOMAG gel and optical CT (VISTA™) in clinical IMRT prostate case
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee S. | - |
dc.contributor.author | Shim J.B. | - |
dc.contributor.author | Chang K.H. | - |
dc.contributor.author | Cao Y. | - |
dc.contributor.author | Yi J. | - |
dc.contributor.author | Park J. | - |
dc.contributor.author | Cho S.J. | - |
dc.contributor.author | Lee S.H. | - |
dc.contributor.author | Huh H. | - |
dc.contributor.author | Cho K.H. | - |
dc.contributor.author | Min C.K. | - |
dc.contributor.author | Yang D.S. | - |
dc.contributor.author | Park Y.J. | - |
dc.contributor.author | Yoon W.S. | - |
dc.contributor.author | Kim C.Y. | - |
dc.date.available | 2020-11-10T12:52:56Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 1742-6588 | - |
dc.identifier.uri | https://scholarworks.korea.ac.kr/kumedicine/handle/2020.sw.kumedicine/31154 | - |
dc.description.abstract | The aims of this study, we present the preliminary results of 3 dimensional dose evaluation software (PDRESS, patient specific dose real evaluation systems). In this work, we compared planned 3D dose distribution with measured 3D dose distribution using a novel normoxic polymer gel dosimeter (TENOMAG) and a commercial cone-beam optical CT scanner (VISTA™, Modus Medical Devices, Inc., London, ON, Canada) to verify the 3D dose distribution in intensity-modulated radiation therapy (IMRT) prostate case. And we developed PDRESS using the Xelis Flatform which is developed by INFINITT Corporation is used to display the 3D dose distribution by loading the DICOM RT Data which is exported from RTP and optical-CT reconstructed VFF file. Data analysis is achieved by comparing the RTP data with the VFF data using profile, gamma map, and DTA. The profiles showed good agreement between RTP data, gel dosimeter, and gamma distribution and the precision of the dose distribution is within ± 5%. The results from this study show that there are no significantly discrepancies between the calculated dose distribution from treatment plan and the measured dose distribution from a TENOMAG gel scanned with an optical CT scanner. The 3D dose evaluation software (PDRESS) which is developed in this study evaluates the accuracy of the three dimensional dose distributions. © 2010 IOP Publishing Ltd. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Physics Publishing | - |
dc.title | Development of PDRESS (patient specific dose real evaluation systems) using a TENOMAG gel and optical CT (VISTA™) in clinical IMRT prostate case | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1088/1742-6596/250/1/012005 | - |
dc.identifier.scopusid | 2-s2.0-78650549818 | - |
dc.identifier.bibliographicCitation | Journal of Physics: Conference Series, v.250, pp 20 - 23 | - |
dc.citation.title | Journal of Physics: Conference Series | - |
dc.citation.volume | 250 | - |
dc.citation.startPage | 20 | - |
dc.citation.endPage | 23 | - |
dc.type.docType | Conference Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Biomedical equipment | - |
dc.subject.keywordPlus | Dosimeters | - |
dc.subject.keywordPlus | Functional polymers | - |
dc.subject.keywordPlus | Radiotherapy | - |
dc.subject.keywordPlus | Scanning | - |
dc.subject.keywordPlus | Urology | - |
dc.subject.keywordPlus | Dose distributions | - |
dc.subject.keywordPlus | Evaluation software | - |
dc.subject.keywordPlus | Gamma distribution | - |
dc.subject.keywordPlus | Intensity-modulated radiation therapy | - |
dc.subject.keywordPlus | Normoxic polymer gel | - |
dc.subject.keywordPlus | Patient specific | - |
dc.subject.keywordPlus | Three-dimensional dose distribution | - |
dc.subject.keywordPlus | Treatment plans | - |
dc.subject.keywordPlus | Computerized tomography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
73, Goryeodae-ro, Seongbuk-gu, Seoul, Republic of Korea (02841)82-2-2286-1265
COPYRIGHT 2020 KOREA UNIVERSITY MEDICAL LIBRARY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.